Procurement Summary
Country: USA
Summary: Overhead Lights
Deadline: 07 Aug 2026
Posting Date: 01 Aug 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 146372466
Document Ref. No.: 36C26226Q1288
Competition: ICB
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
THIS REQUEST FOR INFORMATION (RFI) / SOURCES SOUGHT NOTICE IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES. THIS IS NOT A SOLICITATION.
SOURCES SOUGHT/RFI DESCRIPTION
This is NOT a solicitation announcement. This is a Sources Sought Notice / RFI only. The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 339112 (size standard of 1, 000 Employees). Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published.
The Department of Veterans Affairs (VA) is seeking sources capable of providing Overhead Lights for VA New Mexico Healthcare System located 1501 San Pedro Drive, Southeast, Albuquerque, NM 87108-5153.
The list of DRAFT characteristics is intended to be descriptive, not restrictive, of the supplies/services that are required.
Specifications
Total Arm length must meet or exceed the current lights, which is 85 inches. This must be split nearly equally between the 2 arms lengths of 42 inches and 43 inches to properly fit in the existing patient procedure bay.
Light must have minimum output of Illumination level Ec at 1 meter of 140, 000 lux.
Working distance .8m to 1.2m
Must have a minimum service life of the LEDs: 40, 000 hours.
Color Rendering Index (Ra): 96
Uninstall existing lights (2).
Install 2 new lights according to standards specified in manufacturers installation manual, including wall control. See attached Installation guide from manufacturer.
Provide ceiling mounting kits, single lamp head.
Include 6 Sterilizable Standard Handle, Central, compatible with OR surgical lights.
If your company is interested and capable of providing the required supplies/services, please provide the information indicated below. R...
Notice ID: 36c26226q1288
Department/Ind. Agency: veterans affairs, department of
Sub-tier: veterans affairs, department of
Office: 262-network contract office 22 (36c262)
Product Service Code: 6515 - medical and surgical instruments, equipment, and supplies
NAICS Code: 339112 - Surgical and Medical Instrument Manufacturing
Inactive Dates: sep 06, 2026
Inactive Policy: manual
Documents
Tender Notice
Documents.zip