Notice ID Number NIST-SS25-32
Title: Sources Sought Notice for Optical Reference Cavity
The purpose of this sources sought notice is to conduct market research and identify potential sources of commercial products/services that satisfy the Government-s anticipated needs.
BACKGROUND
The National Institute of Standards and Technology (NIST), Photonics and Optomechanics Group develops cutting-edge nanophotonic and optomechanical devices for metrology, microscopy, and sensing. As part of our research exploring precision timekeeping and navigation with nanophotonics, including nonlinear light sources, we require a high-finesse optical cavity with exquisite frequency stability. The cavity will be used as a frequency discriminator for laser locking, against which we will characterize the noise and frequency stability of nanophotonic sources.
NIST is seeking information from sources that may be capable of providing a solution that will achieve the objectives described above and preliminary requirements below.
One multi-wavelength optical cavity assembly with vacuum housing.
Technical Specifications:
The optical cavity assembly must meet or exceed the following specifications:
Simultaneously usable (as defined by the specifications below) at central wavelengths of 1560 nm, 1060 nm, and 780 nm Usable within a ±10 nm window around each central wavelength Must exhibit cavity finesse 150, 000 in each wavelength region Must enable laser relative frequency instabilities 1×10-15, as quantified by the minimum Allan deviation and obtained by locking the laser frequency to a cavity resonance Must exhibit linear frequency drift The cavity spacer should exhibit a zero-crossing temperature (in its resonance frequency versus temperature curve) between 25 C and 45 C Vacuum housing with internal cavity mounting block, thermal insulation, heaters and thermistors, and a set of windows for each central wavelength, mounted at 2o with respe...
Active Contract Opportunity
Notice ID : NIST-SS25-32
Related Notice
Department/Ind. Agency : COMMERCE, DEPARTMENT OF
Sub-tier : NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY
Office: DEPT OF COMMERCE NIST
General Information
Contract Opportunity Type: Sources Sought (Original)
Original Published Date: Apr 21, 2025 12:10 pm EDT
Original Response Date: May 05, 2025 12:00 pm EDT
Inactive Policy: 15 days after response date
Original Inactive Date: May 20, 2025
Initiative: None
Classification
Original Set Aside:
Product Service Code: 6640 - LABORATORY EQUIPMENT AND SUPPLIES
NAICS Code: 334516 - Analytical Laboratory Instrument Manufacturing
Place of Performance: Gaithersburg, MD 20899 USA