Objective: Replace The Stormwater Drainage Piping With New Hdpe Stormwater Piping.... Tender

CITY OF HAVELOCK has floated a tender for Objective: Replace The Stormwater Drainage Piping With New Hdpe Stormwater Piping. Scope: The Existing Stormwater Drainage Pipe To Be Replaced Is Currently An Rcp Pipe And Is To Be Replaced With A Hp .... The project location is USA and the tender is closing on 24 Apr 2025. The tender notice number is 294-294-03242025, while the TOT Ref Number is 116730261. Bidders can have further information about the Tender and can request the complete Tender document by Registering on the site.

Expired Tender

Procurement Summary

Country : USA

Summary : Objective: Replace The Stormwater Drainage Piping With New Hdpe Stormwater Piping. Scope: The Existing Stormwater Drainage Pipe To Be Replaced Is Currently An Rcp Pipe And Is To Be Replaced With A Hp ...

Deadline : 24 Apr 2025

Other Information

Notice Type : Tender

TOT Ref.No.: 116730261

Document Ref. No. : 294-294-03242025

Financier : Self Financed

Purchaser Ownership : Public

Tender Value : Refer Document

Purchaser's Detail

Name :Login to see tender_details

Address : Login to see tender_details

Email : Login to see tender_details

Login to see details

Tender Details

Objective: Replace The Stormwater Drainage Piping With New Hdpe Stormwater Piping. Scope: The Existing Stormwater Drainage Pipe To Be Replaced Is Currently An Rcp Pipe And Is To Be Replaced With A Hp Stormwater Drainage Pipe. The Existing Rcp Pipe Is Approximately 140 Lineal Feet In Length At A Depth Of Approximately 4.5’ Deep To The Invert Of The Pipe; 24” Diameter And Shall Be Replaced With Hp Stormwater Drainage Pipe To The Same Length, Depth, Diameter And Elevation. The Hp Stormwater Drainage Pipe Is To Be Dual Wall Construction Meeting Astm Standards Including Astm F2881 Or Aashto M330 Type S For Corrugated Pipes. Piping Shall Have A Smooth Interior And Corrugated Exterior With Joining Systems Of Bell And Spigot Couplings. There Shall Also Be A 3’x3’ Inside Diameter Dot Rated Pre-Cast Drop Inlet Installed 70’ From The Upstream End Of The Stormwater Drainage Pipe. The Dot Rated Pre-Cast Drop Inlet Shall Have A Compressive Strength Of No Less Than 4, 000 Psi, Dot Rated Steel Grated Top, And A Design Load Rating Meeting Aashto Hs20 Standards. There Is 55’ Of Curbing Surrounding A Raised Grass Bed, A Portion Of This Curbing Will Have To Be Removed To Access The Rcp Stormwater Drainage Pipe. This Curbing Shall Be Replaced Before The Completion Of This Project. See Figure 4. The Influent And Effluent Stormwater Drainage Pipe Has Concrete Flumes And Will Have To Be Removed During This Project. These Two Concrete Flumes Are To Be Replaced In Kind Before Completion Of This Project. See Figure 5. There Is A Parking Lot Which Is 75’ Long, There Shall Be A 5’ Wide Area Removed For The Stormwater Drainage Pipe Replacement. There Is Also A Driveway Which Is 30’ Long, There Shall Be A 5’ Wide Area Removed For The Stormwater Drainage Replacement. See Figure 6. The Parking Lot And Driveway Are To Be Restored To An As Was Or Better Condition Before The Completion Of This Project

City of Havelock, 2025 Stormwater Drainage Piping Replacement 951 E. Main St., Havelock, NC. 28532

Construction Services
Posted Date : 3/25/2025

Documents

 Tender Notice

Bid-2025-Stormwater-Drainage-Piping-Replacement.pdf


Procurement Documents for USA

Access a comprehensive library of standard procurement documents specific to USA. Here, you'll find all the essential forms, guidelines, and templates required for tender applications and submissions in USA

Explore Procurement Documents for USA


Want To Bid in This Tender?

Get Local Agent Support in USA and 60 More Countries.

View All The Services


View Tenders By


Publish Tenders


Have Any Dispute With The Purchaser?