Procurement Summary
Country : USA
Summary : Mri Door Replacement
Deadline : 05 Jun 2023
Other Information
Notice Type : Tender
TOT Ref.No.: 83522993
Document Ref. No. : 36C26023Q0539
Financier : Self Financed
Purchaser Ownership : Public
Tender Value : Refer Document
Purchaser's Detail
Name :Login to see tender_details
Address : Login to see tender_details
Email : Login to see tender_details
Login to see detailsTender Details
Description
Sources Sought The purpose of this Sources Sought Announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified Service-Disabled Veteran Owned Small Businesses (SDVOSB), Veteran Owned Small Businesses (VOSB), Small Business Manufacturers, other Small Businesses interested and capable of providing items requested. The intended contract is a firm-fixed price contract. A SBA Non-Manufacturer Rule Waiver will not apply if this requirement is set-aside for small business. It does apply to all other socioeconomic small business categories. The Department of Veterans Affairs, NCO20 is looking for BRAND NAME or EQUAL sources of the following: ETS-Lindgren EVO auto-seal STC44 MRI Door Replacement Service. Salient Characteristics: MRI suite door must meet the below requirements. Order is for a REPAIR contract service of MRI Suite door. Conduct RF Diagnostic test prior to any modification work to establish the current baseline performance of RF shield. Remove existing door and jamb and re-work rough opening in shield to accommodate new door. Provide and install one (1) 4'-0" x 7'-0" ETS-Lindgren EVO auto-seal STC44 door with architecturally styled RF door system including hardware. Conduct final RF test after door installation is complete to verify shield performs equal to or better than initial baseline test Must be new equipment only and all items must be covered by manufacturer s warranty. STATEMENT OF WORK (SOW) 1. Contract Title. REPAIR SERVICE CONTRACT FOR REPLACEMENT OF MRI DOOR. 2. Background. This equipment is not easily supported by Biomed or in house maintenance personnel due to its preparatory nature. Installation and repair require specialized knowledge of MRI shielding to install this correctly. These installers work very closely with the MRI manufacturer to absolutely reduce RF noise in the MRI environment. Ex. One small loose screw could cause artifact and downtime affecting patient tr...
Active Contract Opportunity
Notice ID : 36C26023Q0539
Related Notice
Department/Ind. Agency : VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier : VETERANS AFFAIRS, DEPARTMENT OF
Office : 260-NETWORK CONTRACT OFFICE 20 (36C260)
General Information
Contract Opportunity Type: Sources Sought (Updated)
All Dates/Times are: (UTC-07:00) PACIFIC STANDARD TIME, LOS ANGELES, USA
Updated Published Date: May 26, 2023 09:12 am PDT
Original Published Date: May 26, 2023 08:55 am PDT
Updated Response Date: Jun 05, 2023 08:00 am PDT
Original Response Date: Jun 05, 2023 08:00 am PDT
Inactive Policy: Manual
Updated Inactive Date: Jun 20, 2023
Original Inactive Date: Jun 20, 2023
Initiative: None
Classification
Original Set Aside:
Product Service Code: J065 - MAINT/REPAIR/REBUILD OF EQUIPMENT- MEDICAL, DENTAL, AND VETERINARY EQUIPMENT AND SUPPLIES
NAICS Code: 332321 - Metal Window and Door Manufacturing
Place of Performance: Mann-Grandstaff VA Medical Center 4815 N. Assembly St Spokane, WA 99205 USA
Documents
Tender Notice
36C26023Q0539.docx