Procurement Summary
Country: USA
Summary: Moisture Removal Device (electronic chiller system)
Deadline: 21 Aug 2024
Posting Date: 16 Aug 2024
Other Information
Notice Type: Tender
TOT Ref.No.: 105864065
Document Ref. No.: SS-CDC-75D301-2024-10
Competition: ICB
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
Description
The Centers for Disease Control and Prevention (CDC) Office of Acquisitions Services is issuing this Sources Sought Notice on behalf of the National Institute of Occupational Safety and Health (NIOSH) Health Effects Laboratory Division (HELD)
ACQUISITION BACKGROUND AND REQUIREMENT: NIOSH HELD has a requirement to obtain a device that can remove moisture from NIOSH-s Automated Breathing and Metabolic Simulators (ABMS). An ABMS simulates human breathing and metabolism through a mechanical means of respiration. NIOSH uses ABMSs to perform correlation testing, approval testing, and post-market surveillance testing of self-contained self-rescuers and closed-circuit escape respirators. As part of NIOSH-s test studies at the ABMS, it is necessary to remove moisture from the ABMS breathing circuit-s trachea to prevent damage to the measuring cells of the oxygen and carbon dioxide gas analyzers so that the correct concentrations of O2 and CO2 in the breathing gas can be measured.
The required moisture removal device must meet the minimum following salient characteristics:
The device must be able to remove moisture from the ABMS breathing circuit-s simulated trachea to enable the analysis of oxygen and carbon dioxide concentrations in the breathing gas using specialized oxygen and carbon dioxide gas analyzers.
Capable of reducing the dew point of a gas sample flowing at ≤1 Lpm and slightly sub-ambient pressure to
The device must be able to provide a moisture removal magnitude that is sufficient to prevent damage to the gas analyzer-s measuring cells.
The device must also be able to provide an environment where the gas sample system pressure shall be maintained at slightly less than ambient (as induced by the vacuum pump drawing the sample gas through the gas analyzer circuit at ≤1 Lpm).
The device must have 1/8-inch OD X 1/16-inch ID sample gas tubing inlet and outlet connections on its exterior front face to...
Active Contract Opportunity
Notice ID : SS-CDC-75D301-2024-10
Related Notice
Department/Ind. Agency : HEALTH AND HUMAN SERVICES, DEPARTMENT OF
Sub-tier : CENTERS FOR DISEASE CONTROL AND PREVENTION
Office: CDC OFFICE OF ACQUISITION SERVICES
General Information
Contract Opportunity Type: Sources Sought (Original)
All Dates/Times are: (UTC-04:00) EASTERN STANDARD TIME, NEW YORK, USA
Original Published Date: Aug 15, 2024 03:40 pm EDT
Original Response Date: Aug 21, 2024 03:30 pm EDT
Inactive Policy: 15 days after response date
Original Inactive Date: Sep 05, 2024
Initiative: None
Classification
Original Set Aside:
Product Service Code: 6640 - LABORATORY EQUIPMENT AND SUPPLIES
NAICS Code: 423990 - Other Miscellaneous Durable Goods Merchant Wholesalers
Place of Performance: Pittsburgh, PA 15236 USA
Documents
Tender Notice