Procurement Summary
Country: USA
Summary: Mirror Vacuum Chambers And High Precision Mover Systems (Vcms) For L2s-I
Deadline: 03 Jul 2018
Posting Date: 19 Jun 2018
Other Information
Notice Type: Tender
TOT Ref.No.: 24268264
Document Ref. No.: SLAC_L2SI_Vacuum_Chamber_Mirror_System
Competition: ICB
Financier: Self Financed
Purchaser Ownership: -
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
Slac national accelerator laboratory/lcls is seeking a supplier of five mechanical systems as part of the lcls ii scientific instrument(lcs-i) program.
This posting is to identify prospective suppliers for a formal request for proposal. This posting is not a solicitation and does not request or require a proposal. Interested suppliers must respond through the interested vendor tab in this posting.
Each system is composed by two main parts:
a mirror assembly (with mirror holder, bender, and interface plate) designed and/or realized by slac. Two of the three systems will have two mirrors in each chamber. The other three will have a single mirror in each chamber.
The vacuum chamber and mover system (including all the motions, motors, encoders and supports) shall be designed and provided by the supplier. Systems with two mirrors will require two separate mover systems.
The vcms has to be uhv compatible, hosting a 1 meter long mirror (plus its holder, cooling and bender), and provide pointing stability better than 25 nrad rms.
The vendor is responsible for providing complete, tested systems and mechanics, delivered safely to slac, and to participate in the installation of the systems in their final locations. The vendor is responsible for performing all necessary tests, to guarantee that all specifications and requirements are met. The vendor is responsible for providing all necessary documentation to the slac team, to enable future connection, installation, and operation of the vcms, and to maintain them at their specified performance.
All of the motions have to be performed by moving the mirror independent of the chamber. Angular motion as large as 7 mrad with 25 nrad steps and transversal motion as large as 50 mm with 0.01 mm step are required.
The cooling and bending system is designed by slac. Slac will provide the exact location (with respect the mirror optical pole) and dimension of the flanges needed to accommodate them. Slac will al...