Procurement Summary
Country: USA
Summary: Lsm990 Confocal Airyscan 2 Detector Microscope
Deadline: 06 Aug 2026
Posting Date: 29 Jul 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 146102748
Document Ref. No.: 75N98026Q00889
Competition: ICB
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
1. GENERAL INFORMATION This is a combined synopsis/solicitation for commercial products prepared in accordance with the FAR Part 12.1, as supplemented with additional information included in this notice, and in conjunction with FAR Part subpart 13.5 This announcement constitutes the only solicitation; quotations are being requested, and a separate written solicitation will not be issued.
The National Institutes of Health (NIH), National Institute on Deafness and Other Communication Disorders (NIDCD), Intends to contract on a sole source basis with Carl Zeiss Microscopy - One North Broadway, White Plains, NY 10601 to procure a LSM 990 w/Airyscan-2 Detector Microscope consisting of all the items per the attachment provided in this notice.
The Government intends to award a Firm-Fixed-Price Purchase Order resulting from this solicitation.
2. DESCRIPTION OF REQUIREMENT
2.1 Background
The NIDCD uses live cell imaging to view the real-time cellular organelle development and functions. Only the LSM990 proprietary Airyscan detector, which is a 32 channel GaAsP Array, sampling at 0.2AU per detector for a total of 1.25AU of the PSF at every pixel for a resolution of 90nm in XY and 200nm in Z will fulfill our needs. The resolution and sensitivity of the detector is critical for the work with live organ of Corti explants from mouse cochlea to do imaging over multiple days, which requiring the gentlest imaging with the highest level of resolution. Another critical aspect of the experiments is the file sizes and data handling and processing needs. The LSM990 has addressed these concerns, 8x smaller image size for the raw data and 5x faster processing of the final Airyscan data of high-resolution live imaging.
The LSM990 microscope system is needed soon since it allows for high-resolution imaging at much faster speed of acquisition than available on LSM880 to collect live imaging data of the mouse organ of Corti explant for a current project in the laboratory. Liv...
Notice ID: 75n98026q00889
Department/Ind. Agency: health and human services, department of
Sub-tier: national institutes of health
Office: national institutes of health nichd
Product Service Code: 6640 - laboratory equipment and supplies
NAICS Code: 334516 - Analytical Laboratory Instrument Manufacturing
Inactive Dates: aug 07, 2026
Inactive Policy: manual
Documents
Tender Notice
Documents.zip