Statement of Need
The Corporal Michael J. Crescenz VA Medical Center requires additional components for the Leksell stereotactic system specifically to enhance the capabilities for performing Deep Brain Stimulation (DBS) procedures at our facility.
Background
Deep Brain Stimulation (DBS) is a recognized treatment for various neurological conditions, including Parkinson s disease, essential tremor, and dystonia. The procedure involves implanting electrodes within certain areas of the brain to produce electrical impulses that regulate abnormal impulses or affect certain cells and chemicals within the brain.
CMC VAMC uses the Leksell stereotactic system for precise navigation and targeting during these intricate procedures. While the existing system provides a solid foundation, certain components must always have back-ups to maintain the highest standards of care, improve outcome accuracy, and expand the procedural capabilities in line with modern advancements in DBS.
The procurement and integration of these additional back-up components will have a profound impact on our service- delivery.
Salient Characteristics/ Compatibility Requirements: Brand Name or Equal
Needs to be compatible with current Alpha Omega s Neuro Omega platform for Deep Brain Stimulation (DBS)
Accuracy must be within 1 micron (.001 mm).
Must filter, amplify, and digitize signals from the brain up to a foot away from patient head.
Must minimize electromagnetic interference and other types of interference in the room
Must be shielded with Tungsten or other equivalent material
Must also measure Local Field potentials from each micro electrode on the implanted lead
Must include
Sterilization tray for Drive Headstage and Cable
ECoG HeadBox
HeadBox Cable
HeadBox Holder
Transformer Recording Only
Drive and recording HeadStage must be one single assembly with electronic drive
HeadStage must measure...
Notice ID: 36c24426q0631
Department/Ind. Agency: veterans affairs, department of
Sub-tier: veterans affairs, department of
Office: 244-network contract office 4 (36c244)
Product Service Code: 6515 - medical and surgical instruments, equipment, and supplies
NAICS Code: 339113 - Surgical Appliance and Supplies Manufacturing
Inactive Dates: jun 08, 2026
Inactive Policy: manual
Documents
Tender Notice
Documents.zip