Title: Ion mill for transmission electron microscope specimens
The purpose of this sources sought notice is to conduct market research and identify potential sources of commercial products/services that satisfy the Government-s anticipated needs.
BACKGROUND
To support the CHIPS for America Act, the NIST Precision Imaging Facility (PIF) requires an ion milling system to provide final thinning to transmission electron microscope specimens. The coating system is intended to support the scanning electron microscope, focused ion beam, and transmission electron microscope instruments (among others) in the PIF.
NIST is seeking information from sources that may be capable of providing a solution that will achieve the objectives described above, in addition to the following essential requirements:
TECHNICAL REQUIREMENTS:
Line Item 0001: Sputter coater for scanning electron microscopy
Quantity: One (1)
Technical Specifications:
Function
The system shall be capable of milling/polishing specimens for transmission electron microscopy using one or more ion beams.
Chamber/Stage
The system shall be able to hold standard 3 mm diameter transmission electron microscope grids and/or half grids which are typically used during focused ion beam preparation.
The stage shall rotate 360°
Offerors shall comment on the ability of the stage to be cooled using liquid nitrogen
Ion Source(s)
The system shall have two or more independently adjustable ion sources.
The energy of the ion sources shall be adjustable. Offerors shall comment on the ion source energy range.
The angle of the ion sources shall be adjustable relative to the specimen.
Offerors shall comment on whether ion source angles are motorized.
Imaging and illumination
The system shall include a microscope to image the specimen during ion milling.
Illumination of the specimen for microscope imaging shall be ...
Notice ID: nist-ss26-109
Department/Ind. Agency: commerce, department of
Sub-tier: national institute of standards and technology
Office: dept of commerce nist
NAICS Code: 334516 - Analytical Laboratory Instrument Manufacturing
Inactive Dates: may 15, 2026
Inactive Policy: 15 days after response date
Documents
Tender Notice