Procurement Summary
Country : USA
Summary : Intent to Sole Source
Deadline : 21 Jul 2025
Other Information
Notice Type : Tender
TOT Ref.No.: 122685733
Document Ref. No. : 36C25925Q0611
Financier : Self Financed
Purchaser Ownership : Public
Tender Value : Refer Document
Purchaser's Detail
Name :Login to see tender_details
Address : Login to see tender_details
Email : Login to see tender_details
Login to see detailsTender Details
Description
STATEMENT OF NEEDContracting Officer: Jacqueline O BryanVA Name:George E. Wahlen VAMCVA Address:500 S Foothill Dr., SLC, UT 84148E-Mail Address:Jacqueline.Obryan@va.govVendor Name: ADInstrumentsContract Title: NOVA Plus NC System (Basic)Background: Currently, the VA utilizes arm blood pressure cuffs that use sphygmomanometry or automated oscillometry. These devices require that the patient remains completely still during the measurements and provides a single blood pressure value that requires 30-45 seconds per assessment. The Finapres NOVA is a clinical grade, non-invasive, continuous blood pressure monitor for accurate measurement of blood pressure that is determined with every heartbeat. Using proprietary technology, this device also estimates physiologic parameters such as: cardiac output, stroke volume, cardiac contractility, left ventricular ejection time, and total peripheral resistance. Traditional blood pressure cuffs do not provide this information, which are otherwise only available using costly, invasive hemodynamic monitoring. This equipment will be used to support Walter Wray s VA funded project E3343-R titled Efficacy of exercise training in patients with HFpEF . The proprietary finger cuff monitoring system will make it so that accurate measurements of blood pressure and the additional parameters outlined above can be determined during physical activity, ensuring patient safety.Scope: NANO CORE module (double finger cuff system)3 finger cuffs (small, medium, large)Height Correction Unit (HCU)Upper arm module for brachial calibration with upper arm cuffs (small, medium, large)Analog Input- Output module (2 in 8 out)User ManualThe vendor is to supply the needed system and upgrade as outlined and defined by the quote provided: Additional Information/Requirements: Features & ParametersContinuous non-invasive brachial and finger blood pressureNo arm movement restrictions thanks to the HCUBeat-to-beat basic hemodynamic parameters24/7 conti...
Active Contract Opportunity
Notice ID : 36C25925Q0611
Related Notice
Department/Ind. Agency : VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier : VETERANS AFFAIRS, DEPARTMENT OF
Office: NETWORK CONTRACT OFFICE 19 (36C259)
General Information
Contract Opportunity Type: Special Notice (Original)
Original Published Date: Jul 14, 2025 12:07 pm MDT
Original Response Date: Jul 21, 2025 03:00 pm MDT
Inactive Policy: Manual
Original Inactive Date: Aug 20, 2025
Initiative: None
Classification
Original Set Aside:
Product Service Code: 6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES
NAICS Code: 334516 - Analytical Laboratory Instrument Manufacturing
Place of Performance:
Documents
Tender Notice
36C25925Q0611.docx