THIS IS A SOURCES SOUGHT NOTICE FOR MARKET RESEARCH PURPOSES ONLY. This is not a solicitation for proposals, proposal abstracts, or quotations. The purpose of this notice is to obtain information regarding the availability and capability of qualified small businesses (e.g., 8(a), HUBZone, Service-Disabled Veteran-Owned Small Businesses (SDVOSB), Women-Owned Small Businesses (WOSB)) and large businesses to perform the work described below.
1. AGENCY:
Idaho Air National Guard, 124th Fighter Wing, Gowen Field, Boise, ID 83705.
2. PROJECT TITLE:
Direct Digital Controls (DDC) System Replacement
3. NAICS CODE:
The anticipated North American Industry Classification System (NAICS) code for this requirement is 238220 - Plumbing, Heating, and Air-Conditioning Contractors, which has a small business size standard of $19.0 million.
4. PROJECT DESCRIPTION:
The United States Government has a requirement for construction services to replace existing Direct Digital Control (DDC) systems and associated equipment at Gowen Field, Boise, Idaho. The base may be transitioning its building controls to an installation-wide Automated Logic Corporation platform.
The scope of work includes, but is not limited to, the following:
Provide all labor, materials, services, and oversight for the design and installation of a new, open-protocol, web-based DDC system.
Demolish and remove existing controls, cabinets, controllers, and thermostats.
Install and commission new DDC equipment, control modules, wiring, and terminations for equipment such as Air Handling Units (AHUs), Variable Air Volume (VAV) boxes, fan coil units, hot water systems, and pumps.
Provide and install a new BACnet Router/Global Controller and integrate the system with existing building equipment (e.g., boilers).
Map all new control points to the existing Gowen Field front-end server.
Ensure all work complies with current standards, including UFC, IBC, IMC, NEC, NFPA, and ASHRAE....