DEPT OF DEFENSE has floated a tender for Industrial Vacuums. The project location is USA and the tender is closing on 10 May 2024. The tender notice number is W15BW9-24-X-7890, while the TOT Ref Number is 100518550. Bidders can have further information about the Tender and can request the complete Tender document by Registering on the site.

Expired Tender

Procurement Summary

Country : USA

Summary : Industrial Vacuums

Deadline : 10 May 2024

Other Information

Notice Type : Tender

TOT Ref.No.: 100518550

Document Ref. No. : W15BW9-24-X-7890

Competition : ICB

Financier : Self Financed

Purchaser Ownership : Public

Tender Value : Refer Document

Purchaser's Detail

Purchaser : DEPT OF DEFENSE
Contracting Office Address : PICATINNY ARSENAL, NJ 07806-5000
Primary Point of Contact : Mark Zator
mark.zator.civ@army.mil
Phone Number 9737248121

USA
Email :mark.zator.civ@army.mil

Tender Details

Description

This is a Sources Sought (SS) issued by the Army Combat Capabilities Development Command (DEVCOM), Armaments Center (AC), Munitions Engineering & Technology Center (METC) and Aeroballistics Division. This effort is for information to plan a potential acquisition strategy and contract for a vacuum system. The effort supports a wind tunnel facility in building 266. Responders to this SS notice are asked to provide statements with the following information related to meeting requirements:​

A narrative explaining the company-s background, and past/current experience relevant to furnishing and installing any of the aforementioned systems that can create exit conditions of -14.5 PSI (

10 torr or less, 0.1PSIA) for 9-inch test section wind tunnel. There is 120, 000 gallons of air storage (rated 190Psi) available to drive the system. Compressors of the current wind tunnel facility operate at no more than 350 PSI. For a Vacuum System, an estimated 2, 480 cubic feet, vacuum rated storage tank is required. The tank will need to withstand vacuum conditions internally, and barometric conditions externally. The pumps for this system should be able to evacuate the tank in about 30

45 minutes. The Vacuum Blowers need to minimize pressure build up in the tank over a 40 second runtime (objective runtime, 20 second threshold). The system must be able to withstand temperatures as high as a) the outlet temperature of the gas for -14.5 PSI (.01 PSIA) case will be 800 0°F and b) the outlet temperature of the gas for -13.0 PSI (1.8 PSIA) case will be 620°F. Ability to provide training on maintenance, safety, and other handling requirements of the system.Request that all responses included the following information:

Filly Company Name (Legal Entity): Cage Code: Website (if applicable): Contact Information: Business Size Status.
Active Contract Opportunity Notice ID W15BW9-24-X-7890 Related Notice Department/Ind. Agency DEPT OF DEFENSE Sub-tier DEPT OF THE ARMY Office W4MK CCDC ARMAMENTS CENTER
General Information
Contract Opportunity Type: Sources Sought (Original)
All Dates/Times are: (UTC-04:00) EASTERN STANDARD TIME, NEW YORK, USA
Original Published Date: Apr 25, 2024 09:28 am EDT
Original Response Date: May 10, 2024 12:00 pm EDT
Inactive Policy: 15 days after response date
Original Inactive Date: May 25, 2024
Initiative: None

Classification
Original Set Aside:
Product Service Code:
NAICS Code: 333248 - All Other Industrial Machinery Manufacturing

Place of Performance:

Documents

 Tender Notice