Procurement Summary
Country: Canada
Summary: Hvac Upgrades - Construction Services
Deadline: 10 Apr 2026
Posting Date: 13 Mar 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 137701782
Document Ref. No.: GOC375344-CT
Competition: ICB
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
HVAC Upgrades at Prince Rupert Government of Canada Building, which includes, but not limited to: The installation of DX Heat Pump coils in the supply air ductwork downstream of the mechanical unit SF-1. Provide and install 25mm thick thermal insulation on all existing supply air ductwork within the building. Addition of condensing units on the roof requiring electrical power and structural support serving the main air handler SF-1 serving Levels 1 and 2 DFO areas. Addition of refrigerant piping run throughout the building in large volume spaces to serve air handling units DX heat pump coils for the main air handler SF-1 serving Levels 1 and 2 DFO areas. Addition of controls to the existing mechanical DDC system. Addition of CO2 demand control ventilation for the main air handler SF-1 serving Levels 1 and 2 DFO areas. Addition of humidification and dehumidification control for the main air handler SF-1 serving Levels 1 and 2 DFO areas.All disruptive work (including but not limited to, noise, dust, equipment shutdown, hazmat abatement, etc.) must be scheduled afterhours.
Reference Number : 0000316890 Location : Canada, British Columbia, Northern BC Job Location : Prince Rupert GOCB - 417 – 2nd Ave W, Prince Rupert, BC, V8J 1G8 Description : HVAC Upgrades at Prince Rupert Government of Canada Building, which includes, but not limited to: The installation of DX Heat Pump coils in the supply air ductwork downstream of the mechanical unit SF-1. Provide and install 25mm thick thermal insulation on all existing supply air ductwork within the building. Addition of condensing units on the roof requiring electrical power and structural support serving the main air handler SF-1 serving Levels 1 and 2 DFO areas. Addition of refrigerant piping run throughout the building in large volume spaces to serve air handling units DX heat pump coils for the main air handler SF-1 serving Levels 1 and 2 DFO areas. Addition of controls to the existing mechanical DDC system. Addition of CO2 demand control ventilation for the main air handler SF-1 serving Levels 1 and 2 DFO areas. Addition of humidification and dehumidification control for the main air handler SF-1 serving Levels 1 and 2 DFO areas.All disruptive work (including but not limited to, noise, dust, equipment shutdown, hazmat abatement, etc.) must be scheduled afterhours. :
Documents
Tender Notice