Procurement Summary
Country : USA
Summary : High-Throughput Circular Dichroism for Analysis of Biotherapeutics
Deadline : 15 Jul 2025
Other Information
Notice Type : Tender
TOT Ref.No.: 121925630
Document Ref. No. : NIST-MML-25-SS21
Financier : Self Financed
Purchaser Ownership : Public
Tender Value : Refer Document
Purchaser's Detail
Name :Login to see tender_details
Address : Login to see tender_details
Email : Login to see tender_details
Login to see detailsTender Details
Description
National Institute of Standards and Technology (NIST)
Acquisition Management Division,
100 Bureau Drive, Mail Stop 1640,
Gaithersburg, MD, 20899-1640
Sources Sought Notice NIST-MML-25-SS21
Title: High-Throughput Circular Dichroism for Analysis of Biotherapeutics
This is a Sources Sought Notice ONLY. Requests for copies of a solicitation will not receive a response.
This Notice is for planning purposes only and is not a Request for Proposal or Request for Quotation or an obligation on the part of the National Institute of Standards and Technology (NIST) for conducting a follow-on acquisition. NIST does not intend to award a contract on the basis of this Notice, or otherwise pay for the information requested. No entitlement or payment of direct or indirect costs or charges by NIST will arise as a result of submission of responses to this Notice and NIST use of such information.
NO SOLICITATION DOCUMENTS ExIST AT THIS TIME.
NIST is seeking information from vendors potentially capable of providing High-Throughput CD instrument.
SPECIFIC CAPABILITIES:
A fully integrated robotic system for automated sample loading, based on 96-well sample plates or tube racks An intense, continuous light source producing wavelength in the range of 180 nm to 1000 nm, or broader High sensitivity light detector system (avalanche photodiode preferred, for low electronic noise and high spectral response) High sensitivity, permitting measurements of very dilute samples (as low as 0.05 milligram per milliliter of a protein solution) Integrated Nitrogen (N2) purge system Integrated multiple wavelength calibration system that ensures accurate CD values over the entire range (180 nm to 1000 nm ) Measuring simultaneous CD and Absorbance signals Integrated Peltier-based temperature controller for the sample, capable of a temperature range: -10 oC to 100 oC Providing sample plate temperature control in the range of 0 oC to 50 oC, or ...
Active Contract Opportunity
Notice ID : NIST-MML-25-SS21
Related Notice
Department/Ind. Agency : COMMERCE, DEPARTMENT OF
Sub-tier : NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY
Office: DEPT OF COMMERCE NIST
General Information
Contract Opportunity Type: Sources Sought (Original)
Original Published Date: Jul 01, 2025 09:23 am EDT
Original Response Date: Jul 15, 2025 12:00 am EDT
Inactive Policy: 15 days after response date
Original Inactive Date: Jul 30, 2025
Initiative: None
Classification
Original Set Aside:
Product Service Code:
NAICS Code: 334516 - Analytical Laboratory Instrument Manufacturing
Place of Performance: Gaithersburg, MD 20899 USA
Documents
Tender Notice