Procurement Summary
Country: USA
Summary: High Precision Wavemeter
Deadline: 31 Jul 2025
Other Information
Notice Type: Tender
TOT Ref.No.: 123186582
Document Ref. No.: NIST-MML-SS29
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
Description
National Institute of Standards and Technology (NIST),
Acquisition Management Division,
100 Bureau Drive, Mail Stop 1640,
Gaithersburg, MD, 20899-1640
This is a Sources Sought Notice ONLY. Requests for copies of a solicitation will not receive a response.
This Notice is for planning purposes only and is not a Request for Proposal or Request for Quotation or an obligation on the part of the National Institute of Standards and Technology (NIST) for conducting a follow-on acquisition. NIST does not intend to award a contract on the basis of this Notice or otherwise pay for the information requested. No entitlement or payment of direct or indirect costs or charges by NIST will arise as a result of submission of responses to this Notice and NIST use of such information. NIST recognizes that proprietary components, interfaces and equipment, and clearly mark restricted or proprietary components, interfaces and equipment, and clearly mark restricted or proprietary data and present it as an addendum to the non-restricted/non-proprietary information. In the absence of such identification, NIST will assume to have unlimited rights to all technical data in the information paper.
NO SOLICITATION DOCUMENTS ExIST AT THIS TIME.
Minimum Requirement:
NIST is seeking information on contractors who can provide the following:
The Contractor shall provide a benchtop wavemeter meeting the following requirements:
-Measurement accuracy of ≤ 750 MHz and a resolution of ≤ 20 MHz over a wavelength range of 400-800 nm, or wider.
-Measurement speed must be ≥ 4 Hz
-The wavemeter must be able to measure continuous-wave (CW) lasers, and it must have an internal calibration source, automatic temperature corrections, and thermally insulating housing
- The warm-up time under constant ambient conditions must be - The wavemeter must be able to measure a wide range of laser line widths, and it must have a USB interface for computer...
Active Contract Opportunity
Notice ID : NIST-MML-SS29
Related Notice
Department/Ind. Agency : COMMERCE, DEPARTMENT OF
Sub-tier : NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY
Office: DEPT OF COMMERCE NIST
General Information
Contract Opportunity Type: Sources Sought (Original)
Original Published Date: Jul 22, 2025 10:47 am EDT
Original Response Date: Jul 31, 2025 04:00 pm EDT
Inactive Policy: Manual
Original Inactive Date: Aug 01, 2025
Initiative: None
Classification
Original Set Aside: No Set aside used
Product Service Code: 6640 - LABORATORY EQUIPMENT AND SUPPLIES
NAICS Code: 334516 - Analytical Laboratory Instrument Manufacturing
Place of Performance: Gaithersburg, MD 20899 USA
Documents
Tender Notice
NIST-MML-SS29-HighPrecisionWavemeter.pdf