Procurement Summary
Country: USA
Summary: FY26 FCI Phoenix Fire AlarmSuppression System Inspection
Deadline: 20 Jan 2026
Posting Date: 06 Jan 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 133191244
Document Ref. No.: 15B60826Q00000003
Competition: ICB
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
The Bureau of Prisons (BOP), Federal Correctional Institution (FCI) Phoenix located at 37900 N 45th Avenue, intends to procure services for the inspection, cleaning and certifying of the fire detection system in according with National Fire Protection Association (NFPA) 72 and RFO FAR 12. 201-1(c)(2).
The services provided will be consistent with industry standards and policies required by the NFPA and the BOP. The services will be monitored by a representative of the FCI Phoenix Facilities department. The performance of these services will also be verified by the Contracting Officer Representative (COR). Services provided will be under NAICS Code 561621 - Security Systems Services (except Locksmiths).
Fire Detection System:
Contractor will have ten (10) business days (excluding Federal Holidays) to inspect and test 100% of the entire fire detection system. Contractor will clean 20% of the initiating devices (this 20% will be the devices identified by the Contractor as being the closest to detection status), additionally any device that requires a lift or located in difficult spaces will not be excluded from the cleaning. Contractor will test the entire fire detection system as required by the most current edition of NFPA - National Fire Detection Code, and Federal Bureau of Prison policies (Program Statement 4200.12).
Annual testing of fire detection system will include but not limited to: tests of the control panel equipment, functional tests of audible and visual signaling devices and initiating appliances, such as smoke/heat/duct detectors, manual pull stations, water-flow and tamper switches. Contractor will provide a quote for identified deficiencies; if necessary repair is deemed agreeable to the Government, identified deficiencies can be corrected at the time of inspection.
The fire detection system is manufactured by Notifier. It is a fiber networked starting with an ONYXWorks and then to 20 NFS-320 locations, 1 NFS2-640 location and 2 NCA-s...
Notice ID: 15b60826q00000003
Department/Ind. Agency: justice, department of
Original Set Aside: total small business set-aside (far 19.5)
Sub-tier: federal prison system / bureau of prisons
Office: fao
Product Service Code: 1290 - miscellaneous fire control equipment
NAICS Code: 561621 - Security Systems Services (except Locksmiths)
Inactive Dates: feb 04, 2026
Inactive Policy: 15 days after response date