Procurement Summary
Country : USA
Summary : FY25: Lake Nona Medium Voltage Repair
Deadline : 16 Jun 2025
Other Information
Notice Type : Tender
TOT Ref.No.: 120895305
Document Ref. No. : 36C24825Q0885
Financier : Self Financed
Purchaser Ownership : Public
Tender Value : Refer Document
Purchaser's Detail
Name :Login to see tender_details
Address : Login to see tender_details
Email : Login to see tender_details
Login to see detailsTender Details
Description
The Department of Veteran Affairs, Network Contracting Office 08 invites interested Contractors to attend a site visit for the purpose of assessing the issues identified in the government-generated Trouble Call report. This site visit will assist prospective offers in evaluating the work environment and technical requirements in preparation for submitting a quote under the upcoming Request for Quote (RFQ).Instructions:Interested parties must pre-register attendees (no more than two) by providing names to Robert.edwards2@va.gov and rohan.mckenzie@va.gov no later than June 16, 2025, 11:00 AM. Please arrive on time and bring proper identification to gain access to the facility. Site Visit Details:Date: June 17, 2025Time: 10:00 AM (local time)Location: Orlando VA Medical Center at Lake Nona, 13800 Veterans Way, Orlando, FL 32827Meeting Point: Inside the lobby near the pianoPurpose: Visual inspection and discussion of the issue described in Trouble Call ReportFollow-up: Contractor questions will be address on-site and incorporated into the forthcoming RFQ as appropriate.Background:Emergency (generator) power circuit(s) to the Lake Nona clinic are faulted and/or unreliable.The medium voltage circuit DAG-3 is the emergency (generator) circuit powering the Clinic substation SS-CG2; and is the alternate power source for Clinic substation SS-CG1. It was Hi-Pot tested and the report indicated a catastrophic failure on B-phase, requiring both substations to be placed on the alternate circuit (DAG-15) with no redundancy. A visual inspection of manholes EA1-1 and EA1-2 in the duct bank series noted splices in them that show signs corrosion and degradation. Troubleshooting, testing was performed on the circuit and damage to the B-phase conductor insulation is suspected to be localized the within the ductwork itself requiring emergent replacement.The medium voltage circuit DAG-15 is the emergency (generator) circuit powering the Clinic substation SS-CG1 and is the a...
Active Contract Opportunity
Notice ID : 36C24825Q0885
Related Notice
Department/Ind. Agency : VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier : VETERANS AFFAIRS, DEPARTMENT OF
Office: 248-NETWORK CONTRACT OFFICE 8 (36C248)
General Information
Contract Opportunity Type: Special Notice (Original)
Original Published Date: Jun 13, 2025 03:18 pm EDT
Original Response Date: Jun 16, 2025 11:00 am EDT
Inactive Policy: Manual
Original Inactive Date: Aug 15, 2025
Initiative: None
Classification
Original Set Aside:
Product Service Code: J061 - MAINT/REPAIR/REBUILD OF EQUIPMENT- ELECTRIC WIRE AND POWER DISTRIBUTION EQUIPMENT
NAICS Code: 238210 - Electrical Contractors and Other Wiring Installation Contractors
Place of Performance:
Documents
Tender Notice
ATTACHMENT-B-HI-POT-TEST-SHEET-DAG-15.pdf
ATTACHMENT-A-HI-POT-TEST-SHEET-DAG-3.pdf
36C24825Q0885.docx