Procurement Summary
Country : Canada
Summary : Fuel Tank Replacement
Deadline : 20 Jun 2025
Other Information
Notice Type : Tender
TOT Ref.No.: 120419629
Document Ref. No. : GOC5277318-CS
Financier : Self Financed
Purchaser Ownership : Public
Tender Value : Refer Document
Purchaser's Detail
Name :Login to see tender_details
Address : Login to see tender_details
Email : Login to see tender_details
Login to see detailsTender Details
The existing underground storage tank, serving the oil fired furnace, has a nominal storage capacity of 4, 500 litres and is a federally regulated system under SOR/2008-197; it was installed in 1992.However, it is of single wall fiberglass construction; and as such it does not meet the current editionof CSA B139 regarding the single wall construction besides surpassing the end of its useful life (usually 15-20 yrs.). The work under this project is required to: 1. remove the existing UGT following the guidelines and instructions of CSA B139, & applicable codes and standards.2. Install a new adequatelysized aboveground tank(s), The consultant shall investigate options regarding the tank(s)' material, i.e. fiberglass or steel; number of tanks, and its/their location; accordingly recommending the most feasible and code compliant option: a. option of having two tanks, of adequate size, vs. the currentconfiguration of one tankb. placing the above ground new tank(s) in the same location as the underground, i.e. East side of the building, vs. installation indoors in the spare space (off the mechanical rm in the basement), or any other location the consultant perceive to be practical and code compliable.Subsequently, the requirements of CSA B139 in all its aspects of installation shall be followed.For outdoor installation option the required minimum separation requirements to the building and property lines the tank must be 1.5 m from the building and 3.0 m from the property line....
Solicitation Type : RFQ - Request for Quote (Formal)
Reference Number : 0000295312
Location : Canada, Nova Scotia, Cape Breton Island
Delivery Point : 210 George St., Sydney, NS
Purchase Type : One Time Only- Delivery Date:May 31, 2027
Description : The existing underground storage tank, servingthe oil fired furnace, has a nominal storage capacity of 4, 500 litres and is a federally regulated system under SOR/2008-197; it was installed in 1992.However, it is of single wall fiberglass construction; and as such it does not meet the current edition of CSA B139 regarding the single wall constructionbesides surpassing the end of its useful life (usually 15-20 yrs.). The work under this project is required to: 1. remove the existing UGT following the guidelines and instructions of CSA B139, & applicable codes and standards.2. Install a new adequately sized aboveground tank(s), The consultant shallinvestigate options regarding the tank(s)' material, i.e. fiberglass or steel; number of tanks, and its/their location; accordingly recommending the most feasible and code compliant option: a. option of having two tanks, of adequate size, vs. the current configuration of one tankb. placing the aboveground new tank(s) in the same location as the underground, i.e. East side of the building, vs. installation indoors in the spare space (off the mechanical rm in the basement), or any other location the consultant perceive to be practical and code compliable.Subsequent...
Documents
Tender Notice