Procurement Summary
Country : USA
Summary : Fire Suppression
Deadline : 09 Jul 2025
Other Information
Notice Type : Tender
TOT Ref.No.: 121900051
Document Ref. No. : SapphireFireSuppression
Financier : Self Financed
Purchaser Ownership : Public
Tender Value : Refer Document
Purchaser's Detail
Name :Login to see tender_details
Address : Login to see tender_details
Email : Login to see tender_details
Login to see detailsTender Details
Description
This is a request for information ONLY. No solicitation will be issued at this time. Participation in this effort is strictly voluntary with no cost or obligation to be incurred by the U.S. Government.
Army Contracting Command - Rock Island (ACC-RI) is investigating the market capability to provide Sapphire Fire Suppresion system Maintenance and Services in accordance with:
Contract must meet or exceed the following requirements:
Technicians must be trained on Sapphire Suppression System maintenance and repair. Fire protection systems shall be designed in accordance with NFPA 2001 and Unified Facilities Criteria (UFC) 3-601-02; Fire Protection Systems, Inspection, Testing, And Maintenance. The system repairs and maintenance must be operable to mitigate a fire if it were to ignite in Room 161A. The Sapphire Fire Suppression in NEC RIA B. 350, 1st floor, Room 161A, 162, and 162A system must be repaired to full functionality, and verified that enough chemical to ensure the entirely of the space is protected in the event of an emergency. In B. 350, 1st floor, room 161A must have necessary parts repaired so the system can fire (1-Suppression release peripheral, 1-Coil supervision module, 1-Maintenance bypass switch, 1-Retest System, and 1-Labor to install). The unit will require an adequate volume of Novec 1230 to protect the room with a 4.5% design concentration to suppress a fire for energized electrical equipment per NFPA 2001. The system must have: 1-Tank with 79lbs. of Novec 1230, 1-Bracket, 1-Nozzle, 1-Pneumatic Actuator, 1-Discharge piping, 1-Engineering, and 1-Labor to install. In B. 350, 1st floor, room 162, this room currently does not have enough Novec 1230 to protect the room. The room must have a 4.5 % design concentration to suppress a fire for energized equipment per NFPA 2001. The following is needed: 1-Tank with 105lbs. of Novec 1230, 1-Bracket, 3-Nozzle-s, 1-Pneumatic Actuator, 1-Discharge piping, 1-Engineering, and 1-Labor t...
Active Contract Opportunity
Notice ID : SapphireFireSuppression
Related Notice
Department/Ind. Agency : DEPT OF DEFENSE
Sub-tier : DEPT OF THE ARMY
Major Command : AMC
Sub Command : ACC
Sub Command 2 : ACC-CTRS
Sub Command 3 : ACC RI
Office : W6QK ACC-RI
General Information
Contract Opportunity Type: Sources Sought (Original)
Original Published Date: Jul 01, 2025 02:23 pm CDT
Original Response Date: Jul 09, 2025 02:00 pm CDT
Inactive Policy: 15 days after response date
Original Inactive Date: Jul 24, 2025
Initiative: None
Classification
Original Set Aside:
Product Service Code: J012 - MAINT/REPAIR/REBUILD OF EQUIPMENT- FIRE CONTROL EQUIPMENT
NAICS Code: 811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
Place of Performance: Rock Island, IL 61299 USA
Documents
Tender Notice