SASKATCHEWAN HEALTH AUTHORITY has floated a tender for Fire and Sprinkler System Annual Certification Services. The project location is Canada and the tender is closing on 26 Apr 2024. The tender notice number is RFP400031124, while the TOT Ref Number is 99708816. Bidders can have further information about the Tender and can request the complete Tender document by Registering on the site.

Expired Tender

Procurement Summary

Country : Canada

Summary : Fire and Sprinkler System Annual Certification Services

Deadline : 26 Apr 2024

Other Information

Notice Type : Tender

TOT Ref.No.: 99708816

Document Ref. No. : RFP400031124

Competition : ICB

Financier : Self Financed

Purchaser Ownership : Public

Tender Value : Refer Document

Purchaser's Detail

Purchaser : SASKATCHEWAN HEALTH AUTHORITY
Response Address : Saskatchewan Health Authority
103 Hospital DriveSaskatoon, SK, CanadaS7N 0W8
Contact:
Katelyn Wiederhold
Phone:
Email: katelyn.wiederhold@saskhealthauthority.ca

Canada
Email :katelyn.wiederhold@saskhealthauthority.ca

Tender Details

1) This inspection and testing will include but is not limited to: a) Annunciation equipment such as Field Transponders, Alarm Panels b) Control & Field Peripherals such as Addressable Pull Stations(2- stage), Addressable smoke detectors, Addressable Duct Detectors, Control Module Contacts, Water-flow Switch Monitor Modules, Tamper Switch Monitor Modules, Phone Jacks or Warden Stations, Addressable Heat Detectors, Speakers, Horns and/or Strobes, Annunciation devices, press operations switches, line isolation modules and other peripherals and end of line devices. 2) Water based fire suppression system components such as fire pumps, hydrants, stand pipes as well as water spray fixed systems, foam-water sprinkler systems and foam-water spray systems, and dry pipe systems, depending on how each facility is equipped. a) Sprinkler heads that need to be tested need to be submitted to a recognized laboratory b) Hydrostatic testing from the external FDC to the check valve (Where equipped), as well as flow testing and pressure testing. c) System monitoring devices such as Pressure, Tamper and Solenoid Devices. 3) These services are required by legislation for all facilities having life safety fire systems and all testing needs to be in compliance with the legislation. An inspection report for each facility, detailing the results of the inspection will be provided upon completion of the testing to satisfy the JHA and to maintain SHA-s Certificate of Occupancy. a) Any deficiencies noted during the inspection will be communicated to SHA upon the completion of each inspection. With prior approval, the vendor may address the deficiencies while on site, or return to address depending on circumstances.
1) This inspection and testing will include but is not limited to: a) Annunciation equipment such as Field Transponders, Alarm Panels b) Control & Field Peripherals such as Addressable Pull Stations(2- stage), Addressable smoke detectors, Addressable Duct Detectors, Control Module Contacts, Water-flow Switch Monitor Modules, Tamper Switch Monitor Modules, Phone Jacks or Warden Stations, Addressable Heat Detectors, Speakers, Horns and/or Strobes, Annunciation devices, press operations switches, line isolation modules and other peripherals and end of line devices. 2) Water based fire suppression system components such as fire pumps, hydrants, stand pipes as well as water spray fixed systems, foam-water sprinkler systems and foam-water spray systems, and dry pipe systems, depending on how each facility is equipped. a) Sprinkler heads that need to be tested need to be submitted to a recognized laboratory b) Hydrostatic testing from the external FDC to the check valve (Where equipped), as well as flow testing and pressure testing. c) System monitoring devices such as Pressure, Tamper and Solenoid Devices. 3) These services are required by legislation for all facilities having life safety fire systems and all testing needs to be in compliance with the legislation. An inspection report for each facility, detailing the results of the inspection will be provided upon completion of the testing to satisfy the JHA and to maintain SHA’s Certificate of Occupancy. a) Any deficiencies noted during the inspection will be communicated to SHA upon the completion of each inspection. With prior approval, the vendor may address the deficiencies while on site, or return to address depending on circumstances.
Additional Information:
4) These Fire System and Sprinkler System Certifications services will provide SHA with a signed inspection certificate for each site referencing all particulars including: a) device counts, b) Inspection date c) Deficiencies found, and repaired d) ...