Procurement Summary
Country: USA
Summary: Fire Alarm & Wet Pipe Sprinkler Installation, Federal Courthouse/Post Office, Texarkana, Ar
Deadline: 22 Aug 2017
Posting Date: 25 Jul 2017
Other Information
Notice Type: Tender
TOT Ref.No.: 15089312
Document Ref. No.: 47PH0517R0004
Competition: ICB
Financier: Self Financed
Purchaser Ownership: -
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
The general services administration, public building service is seeking sources capable of performing the installation of a new fire alarm and sprinkler system in the u.s. Post office & courthouse, 500 state line ave, texarkana, ar.
This will be a design build turn-key project for services to install a wet pipe fire sprinkler system. The gsa fpe (fire protection engineer) will provide the specification for both system fa & sprinkler.
The present fire alarm system (installed in 2016) is a siemens xls-iq system and only siemens equipment, appliances and panels are compatible and ul listed for the siemens fire alarm system. As such, utilizing a different brand of fire alarm equipment would render the current facp useless and be a substantial cost to the government.
Due to the proprietary nature of the equipment, it is necessary to limit the procurement of this new system to authorized distributors of the siemens fire alarm system. Additionally, any bidding contractor shall be licensed in the state of arkansas. They shall also be an authorized distributor of the manufacturer in order to purchase components, obtain siemens technical support and be able to program the system for all functions. The authorized siemens contractor shall provide a complete and functional new siemens, intelligent, addressable, voice fire alarm system throughout the building.
All sprinkler work shall be in compliance with gsa design guide p-100 and nfpa 13 (2013 edition) requirements. The sprinkler system shall utilize quick response heads, white, located center of tile, excluding any sidewall, upright or detention style heads. The sprinkler system shall be designed using a minimum design area of 1, 500sf and a water supply safety factor of 10%. All piping shall meet nfpa 13 and p-100 requirements. Fittings shall be cast iron or malleable threaded fittings. Threadable lightwall/thinwall pipe, flex heads, mechanical t s and double escutcheon heads shall not be used.
All co...