Procurement Summary
Country : USA
Summary : Equipment, NON-INVASIVE VASCULAR SYSTEMS, BATTLE CREEK
Deadline : 22 Jul 2025
Other Information
Notice Type : Tender
TOT Ref.No.: 122847420
Document Ref. No. : 36C25025Q0747
Financier : Self Financed
Purchaser Ownership : Public
Tender Value : Refer Document
Purchaser's Detail
Name :Login to see tender_details
Address : Login to see tender_details
Email : Login to see tender_details
Login to see detailsTender Details
Description
This is a SOURCES SOUGHT request for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time. This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine the following:The interest and capability of small business, especially service disabled veteran owned small business and veteran owned small business;Whether the business source is a manufacturer or authorized distributor, verified by an authorization letter from the original equipment manufacturer; andSize classification relative to the North American Industry Classification System (NAICS) code 339112 or the proposed acquisition.The Department of Veterans Affairs, Network Contracting Office 10 is seeking potential sources for Computerized Vascular Systems to be provided for the Battle Creek VA Medical Center, 5500 Armstrong Rd, Battle Creek, MI 49037Salient Characteristics/Statement of Need or WorkComputerized Vascular SystemsGeneral: This request is for two additional Non-Invasive Vascular Systems for Radiology Service. Radiology has seen requests for ABI/TBI and vascular ultrasound requests multiply drastically over the past few years as Podiatry and other specialty services have grown. The C&A requirements do not apply, and a Security Accreditation Package is not required.Warranty Requirements: Six months warranty on Doppler probes, PPG sensors, and on BP cuffs and bladders, 24-month mail back warranty on parts and labor on remainder of unit.Technical Specifications (Exact Requirements): Requirement is for 2 Computerized Vascular Systems: Recommended FLO-LAB 2100-Sx2 or EquivalentAbility to perform the following assessments:Lower Extremity:Segmental PressuresAnkle Brachial Index (ABI)Toe Brachial Index (TBI)Lower Arterial CompletePulsesDoppler (Arterial & Venous)Pulse Volume RecordingDigits (TBI)Raynaud sUpper Extremity:Wrist Brachial IndexUpper Arte...
Active Contract Opportunity
Notice ID : 36C25025Q0747
Related Notice
Department/Ind. Agency : VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier : VETERANS AFFAIRS, DEPARTMENT OF
Office: 250-NETWORK CONTRACT OFFICE 10 (36C250)
General Information
Contract Opportunity Type: Sources Sought (Original)
Original Published Date: Jul 16, 2025 01:11 pm EDT
Original Response Date: Jul 22, 2025 12:00 pm EDT
Inactive Policy: Manual
Original Inactive Date: Aug 21, 2025
Initiative: None
Classification
Original Set Aside:
Product Service Code: 6525 - IMAGING EQUIPMENT AND SUPPLIES: MEDICAL, DENTAL, VETERINARY
NAICS Code: 339112 - Surgical and Medical Instrument Manufacturing
Place of Performance: VA Medical Center Battle Creek, 49037 USA
Documents
Tender Notice
36C25025Q0747.docx