Procurement Summary
Country : USA
Summary : Ent Fusion System
Deadline : 19 Mar 2025
Other Information
Notice Type : Tender
TOT Ref.No.: 116219759
Document Ref. No. : 36C25025Q0399
Financier : Self Financed
Purchaser Ownership : Public
Tender Value : Refer Document
Purchaser's Detail
Name :Login to see tender_details
Address : Login to see tender_details
Email : Login to see tender_details
Login to see detailsTender Details
Description
Brand Name Item: Stealth Station S8 Navigation SystemThe StealthStation S8 is an intraoperative surgical navigation system that is used to guide ENT procedures. It is a computer-based workstation that loads MRI and CT scans and used an optical or electromagnetic tracking system that co-registers the patients anatomy with the MRI/CT scans and tracks sterile instruments during surgery. Essential/significant physical, functional, or performance characteristics.Navigation system must have 2 large, high definition, 27-inch touchscreen monitors provide ultimate flexibility in interacting with the system Unit must have 2 electromagnetic emitter designs, and must have each with large tracking volume The unit must include 1 terabyte solid-state drive for ample space to store large patient exams System must also include 16GB of RAM memory for fast performance and image manipulation Optical camera must come with large tracking volume provides flexibility in positioning and addresses line of sight issuesSurgical navigation system must have a Multi-Dimensional surgical imaging systemIncluded must be a dual cart system design: each cart has 27-inch multi-touch monitor and independent workstation for flexibility There must be ample storage options for accessories Consistent user interface is essential across all software applicationsEquipment must provide both 2D fluoro and 3D image data from the same deviceNavigation visuals must enable 3D imaging in the OR for registration, intra-operative adjustments, and implant confirmationVisualization function must have 3D imaging and visualization of shunts, leads, and electrodes during cranial proceduresUnit must provide flexibility to match image needs intra-operativelyNavigation computer must have assisted navigation and intraoperative imaging during pedicle screw placement in spinal surgerySurgical system must have breakable gantry that opens to allow lateral patient accessComplete unit must allow full mobility for use ...
Active Contract Opportunity
Notice ID : 36C25025Q0399
Related Notice
Department/Ind. Agency : VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier : VETERANS AFFAIRS, DEPARTMENT OF
Office: 250-NETWORK CONTRACT OFFICE 10 (36C250)
General Information
Contract Opportunity Type: Combined Synopsis/Solicitation (Original)
Original Published Date: Mar 12, 2025 10:21 am EDT
Original Date Offers Due: Mar 19, 2025 09:00 am EDT
Inactive Policy: 15 days after date offers due
Original Inactive Date: Apr 03, 2025
Initiative: None
Classification
Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
Product Service Code: 6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES
NAICS Code: 339113 - Surgical Appliance and Supplies Manufacturing
Place of Performance: Detroit, MI 48201 USA
Documents
Tender Notice
36C25025Q0399_1-rfq.docx
Tech-specs.docx
BNJ.doc
Salient-Characteristics.docx