Procurement Summary
Country: USA
Summary: Electrical Inspection, Testing Maintenance Follow on Base Start 11125
Deadline: 10 Nov 2025
Other Information
Notice Type: Tender
TOT Ref.No.: 129204225
Document Ref. No.: 36C25026Q0069
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
Questions and Answers from RFQ 36C25026Q0069 The Item 0001 apparently refers to the set of all other items listed below it. Should the price fields for Item 0001 be left blank, or should they show the total sum of the other items? It can show the total amount of the job No test specifications were provided. Can you provide test specifications or the latest test report as an example? Test specifications will be submitted with the revision. See 3.C. Work items, definitions, and references shall comply with the latest edition of the NETA Maintenance Testing Specifications (MTS) and with the VHA Directive, Electrical Power Distribution System. Below is a list of electrical equipment that shall be maintained and tested: Regarding Item 0003: Can MV Liquid Filled Transformers testing be limited to oil sampling, and inspection? NO Per 3.C. If the answer to the previous question is no, should we perform tests for Polarization Index, Excitation Current, Turns Ratio, Insulation and Winding Resistance on the MV Transformers? Regarding Item 0004: Are the (24) dry-type transformers listed low-voltage transformers? Information provided in Section C of the Statement of Work Is it really necessary to test all (550) circuit breakers by primary injection, or can they be tested by secondary injection? Primary Injection is required for all Frame 250Amp and higher Regarding Item 0009: Should the cables be tested using the VLF method? Megger Testing Regarding Item 0010: Is it necessary to perform insulation tests on the panels, or can they simply be visually inspected? See 3.C. Regarding Item 0011: Please explain in more detail what these (300) Phenolic Labels would be. Are they name tags or another type? Will the VA provide the files for printing? Please provide details and dimensions of the labels. Electrical catalog contains Phenolic Labels Does Item 0013 require scanning only the equipment listed in the other items, or is there a separate inventory/list...
Notice ID :36C25026Q0069 ☺ Related Notice (blank) ☺ Contract Opportunity Type Solicitation☺ Contract Line Item Number (blank)☺ Inactive Dates Dec 10, 2025☺ Inactive Policy Manual☺ Date Offers Due Nov 10, 2025 12:00 PM EST☺ Published Date Oct 30, 2025 5:12 PM EDT☺
Department/Ind. Agency :VETERANS AFFAIRS, DEPARTMENT OF Sub-tier VETERANS AFFAIRS, DEPARTMENT OF Office 506-ANN ARBOR (00506)Classification Original Set Aside (blank) Product Service Code J061 - MAINT/REPAIR/REBUILD OF EQUIPMENT- ELECTRIC WIRE AND POWER DISTRIBUTION EQUIPMENT NAICS Code 561210 - Facilities Support Services Place of Performance (blank) Initiative None Description Questions and Answers from RFQ 36C25026Q0069 The Item 0001 apparently refers to the set of all other items listed below it. Should the price fields for Item 0001 be left blank, or should they show the total sum of the other items? It can show the total amount of the job No test specifications were provided. Can you provide test specifications or the latest test report as an example? Test specifications will be submitted with the revision. See 3.C. Work items, definitions, and references shall comply with the latest edition of the NETA Maintenance Testing Specifications (MTS) and with the VHA Directive, Electrical Power Distribution System. Below is a list of electrical equipment that shall be maintained and tested: Regarding Item 0003: Can MV Liquid Filled Transformers testing be limited to oil sampling, and inspection? NO Per 3.C. If the answer to the previous question is no, should we perform tests for Polarization Index, Excitation Current, Turns Ratio, Insulation and Winding Resistance on the MV Transformers? Regarding Item 0004: Are the (24) dry-type transformers listed low-voltage transformers? Information provided in Section C of the Statement of Work Is it really necessary to test all (550) circuit breakers by primary injection, or can they be tested by secondary injection? Primary Inj...
Documents
Tender Notice