Procurement Summary
Country: Canada
Summary: Correction of the Domestic Water Network and Replacement of Booster Pumps
Deadline: 11 Jun 2026
Posting Date: 13 May 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 141163131
Document Ref. No.: GOC986995-E
Competition: ICB
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_detailsLogin to see details
Tender Details
Overview of the scope of work: The project consists of carrying out the work below (non-exhaustive list): Replacement of the booster group (three booster pumps) and its components (piping, DDC control panel, support, piping, thermal insulation, PVC covering, etc.) Adding an expansion tank Purging existing and new water networks Carry out a water analysis by an accredited laboratory and obtain the results within 24 hours Carry out related work by the exclusive supplier of the building Expand the existing cleanliness slab Replace 27 stopcocks and a check valve (coordination to be carried out with the building maintenance team), as well as thermal insulation and PVC covering Replacement of a heat exchanger, its related work (piping, thermal insulation, PVC covering, etc.), construction of a new cleaning slab and painting Carry out asbestos removal work in collaboration with the industrial hygienist. Refer to Appendix 4 (plans and specifications) for all the details
Reference Number: 0000321963 Location: Canada, Quebec, Ile-de-Montreal Job Location: Project location: Complexe Guy-Favreau, 200 Boul. René-Lévesque West, Montreal, QC H2Z 1X4 Description: Overview of the scope of work: The project consists of carrying out the work below (non-exhaustive list): Replacement of the booster group (three booster pumps) and its components (piping, DDC control panel, support, piping, thermal insulation, PVC covering, etc.) Addition of a tank expansion Carry out the purge of existing and new water networks Carry out a water analysis by an accredited laboratory and obtain the results within 24 hours Carry out related work by the building's exclusive supplier Expand the slab existing cleanliness Replace 27 shut-off valves and a check valve (coordination to be carried out with the building maintenance team), as well as thermal insulation work and PVC covering Replacement of a heat exchanger, its related work (piping, thermal insulation, PVC covering, etc.), construction of a new cleanliness slab and painting Carry out asbestos removal work in collaboration with the industrial hygienist. Refer to Appendix 4 (plans and quote) for all the details:
Documents
Tender Notice