Procurement Summary
Country : Canada
Summary : Consultant - Piping Study
Deadline : 02 Jun 2025
Other Information
Notice Type : Tender
TOT Ref.No.: 119229799
Document Ref. No. : GOC6474038-CS-REV
Financier : Self Financed
Purchaser Ownership : Public
Tender Value : Refer Document
Purchaser's Detail
Name :Login to see tender_details
Address : Login to see tender_details
Email : Login to see tender_details
Login to see detailsTender Details
The study is required to assess the conditions and the compliance of the plumbing and drainage piping, i.e. domestic cold, hot, recirculation, vents, sanitary and storm drainage piping including roof and sanitary drains. Some of the piping run behind walls and above ceilings where access might be achallenge, as well as some have asbestos insulation . The consultant shall: 1. Carry out a detailed and in depth site investigation of the existing piping including visual investigation, non-destructive examination, i.e. Ultrasonic, Camera scope (CCTV), etc., as applicable to evaluate the pipingconditions and compliance. 2.Review the existing drawings and building conditions report and determine the best locations of the pipes where the ultrasonic testing will be performed. Piping shall be assessed in the perimeter area as well as the core of the building. CCTV camera inspection of thesanitary and storm piping shall be done on the entire length of the main pipes and shall follow the pipes until they exit the building. 3.All findings shall be provided in a detail report including pictures, locations of the pipe tests, length of pipe required for replacement (as applicable) and asummary of the recommendations proposed to address any found issues; each recommendation is to be presented with the required timeline to achieve it, associated risks and challenges, cost D estimate and its pros and cons. Consultant shall also promptly identify and notify the building project andproperty ...
Solicitation Type : RFQ - Request for Quote (Formal)
Reference Number : 0000293720
Location : Canada, Ontario, ON - 31 - Waterloo
Delivery Point 166 Frederick Street Kitchener, Ontario Canada N2H 0A9
Purchase Type : One Time Only- Delivery Date:Mar 26, 2026
Description : The study is required toassess the conditions and the compliance of the plumbing and drainage piping, i.e. domestic cold, hot, recirculation, vents, sanitary and storm drainage piping including roof and sanitary drains. Some of the piping run behind walls and above ceilings where access might be a challenge, as well as somehave asbestos insulation . The consultant shall: 1. Carry out a detailed and in depth site investigation of the existing piping including visual investigation, non-destructive examination, i.e. Ultrasonic, Camera scope (CCTV), etc., as applicable to evaluate the piping conditions and compliance. 2.Reviewthe existing drawings and building conditions report and determine the best locations of the pipes where the ultrasonic testing will be performed. Piping shall be assessed in the perimeter area as well as the core of the building. CCTV camera inspection of the sanitary and storm piping shall be doneon the entire length of the main pipes and shall follow the pipes until they exit the building. 3.All findings shall be provided in a detail report including pictures, locations of the pipe tests, length of pipe required for replacement (as applicable) and a summary ofth...