Procurement Summary
Country: Canada
Summary: Consultant - Fire Separation Study and Plan Development
Deadline: 31 Jul 2026
Posting Date: 21 Jul 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 145579695
Document Ref. No.: GOC3692097-CS-SAM
Competition: ICB
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
Assess adequacy of fire separations and fire stopping in the building in comparison with the National Building Code and determine and identify any area within the fire separations that require modifications to comply with the current NBC. Areas that are considered fire separations include, but not limited to, corridors, exit stairwells, service rooms/spaces, mechanical rooms, electrical rooms, boiler rooms, elevator shafts and janitor closets. Scope will include doors, door openings, and hardware for stairwell doors, fire exit doors, doors to mechanical rooms, electrical rooms and janitor's closets. Also, noted penetrations in mechanical rooms, electrical rooms, janitor's closets, and vertical shafts and ducts must be fire stopped at the appropriate fire rating. Study should include cost to correct deficiencies in fire separations. Consultant to provide drawings identifying fire separations and provide estimated cost to correct identified deficiencies.Work to be completed by February 26, 2027.
Solicitation Type : RFQ - Request for Quote (Formal) Reference Number : 0000327707 Location : Canada, Ontario, ON - 44 - Niagara Delivery Point : 32-46 Church St., St. Catherines, Ontario Purchase Type : One Time Only- Delivery Date:Feb 26, 2027 Description : Assess adequacy of fire separations and fire stopping in the building in comparison with the National Building Code and determine and identify any area within the fire separations that require modifications to comply with the current NBC. Areas that are considered fire separations include, but not limited to, corridors, exit stairwells, service rooms/spaces, mechanical rooms, electrical rooms, boiler rooms, elevator shafts and janitor closets. Scope will include doors, door openings, and hardware for stairwell doors, fire exit doors, doors to mechanical rooms, electrical rooms and janitor's closets. Also, noted penetrations in mechanical rooms, electrical rooms, janitor's closets, and vertical shafts and ducts must be fire stopped at the appropriate fire rating. Study should include cost to correct deficiencies in fire separations. Consultant to provide drawings identifying fire separations and provide estimated cost to correct identified deficiencies.Work to be completed by February 26, 2027.
Documents
Tender Notice