Procurement Summary
Country: Canada
Summary: Cns Cooling System Replacement
Deadline: 06 Feb 2026
Posting Date: 14 Jan 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 133653006
Document Ref. No.: GOC2777088-CM
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
This project involves the complete renewal of the chilled-water cooling infrastructure at 291 York Avenue to restore reliable, energy‑efficient, year‑round cooling and heating capacity for the facility. The work includes the removal of the existing failed water-cooled chiller, obsolete cooling tower, and fluid cooler, followed by the supply and installation of a new chilled‑water plant, including a new cooling tower, pumps, heat exchangers, piping modifications, and upgraded DDC controls. The project also includes conversion of the building-s air-handling equipment from DX cooling to chilled‑water coils and replacement of indirect gas-fired heating sections with new hot‑water coils. All construction, tie-ins, and commissioning activities must be executed while maintaining continuous building operations and cooling.Under a CCDC 5B Construction Management Contract, the Construction Manager (CM) will provide comprehensive pre‑construction, construction, commissioning coordination, close‑out, and post‑construction services as described in Schedules A1 & A2, this RFP, and project-specific requirements. Responsibilities begin with a brief transition period to become fully familiar with the completed design, commissioning plan, project requirements, and execution strategy. Following this transition, the CM will assume full control of the construction site and retain responsibility until all work is completed, commissioned, accepted, and closed out.The CM-s services include construct...
Reference Number : 0000311200 Location : Canada, Manitoba, Winnipeg Description : This project involves the complete renewal of the chilled-water cooling infrastructure at 291 York Avenue to restore reliable, energy‑efficient, year‑round cooling and heating capacity for the facility. The work includes the removal of the existing failed water-cooled chiller, obsolete cooling tower, and fluid cooler, followed by the supply and installation of a new chilled‑water plant, including a new cooling tower, pumps, heat exchangers, piping modifications, and upgraded DDC controls. The project also includes conversion of the building’s air-handling equipment from DX cooling to chilled‑water coils and replacement of indirect gas-fired heating sections with new hot‑water coils. All construction, tie-ins, and commissioning activities must be executed while maintaining continuous building operations and cooling.Under a CCDC 5B Construction Management Contract, the Construction Manager (CM) will provide comprehensive pre‑construction, construction, commissioning coordination, close‑out, and post‑construction services as described in Schedules A1 & A2, this RFP, and project-specific requirements. Responsibilities begin with a brief transition period to become fully familiar with the completed design, commissioning plan, project requirements, and execution strategy. Following this transition, the CM will assume full control of the construction site and retain responsibility until all wo...
Documents
Tender Notice