Summary: chiller replacement roybal campus
Deadline: 18 Feb 2026
Posting Date: 05 Feb 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 135124091
Document Ref. No.: 75D301-26-R-73398
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
THIS IS A SOURCES SOUGHT NOTICE. THIS IS NOT A REQUEST FOR PROPOSALS, QUOTATIONS OR BIDS. THERE WILL NOT BE A SOLICITATION, SPECIFICATIONS, OR DRAWINGS AVAILABLE AT THIS TIME.
The Centers for Disease Control and Prevention (CDC) will likely issue a solicitation, as a Request for Proposal (RFP), for design build construction services for a central plant modernization and chiller replacement at the CDC Roybal campus located at 1600 Clifton Rd., Atlanta, GA 30329 in calendar year 2026.
CDC requests letters of interest from qualified SMALL AND LARGE BUSINESS MECHANICAL CONTRACTORS THAT CAN PERFORM AS A PRIME GENERAL CONTRACTOR on the planned central plant modernization and chiller replacement in Atlanta, Georgia.
By way of this Sources Sought, CDC intends to determine the extent of capable firms that are engaged in providing the construction services described hereunder.
Responses to this notice are not offers and cannot be accepted by the U.S. Government to form a binding contract. It is the responsibility of the interested parties to monitor this site for additional information pertaining to this notice. Response to this Request for Information is not mandatory for consideration in any subsequent Request for Proposal.
The Modernization will include design build mechanical work including replacement of four existing 1, 450 ton chillers with 1, 800 ton chillers, replacement of eight cooling towers and four chilled water pumps. Due to the 24/7 operation of the central plant and campus demands; of the 4 chillers to be replaced only 2 can be taken out of operation and bypass piping will need to be installed to facilitate shutdown. Contracting performing work must have a 2 hour emergency response time. Electrical work includes installation of two new Motor Control Centers (MCC), replacing medium voltage (MV) starters and recircuiting. The project also involves, building automation systems (BAS), fire protection, architectural and structural work. As part of the...
Notice ID: 75d301-26-r-73398
Department/Ind. Agency: health and human services, department of
Sub-tier: centers for disease control and prevention
Office: cdc office of acquisition services
Product Service Code: z2nb - repair or alteration of heating and cooling plants
NAICS Code: 238220 - Plumbing, Heating, and Air-Conditioning Contractors