Procurement Summary
Country: Ukraine
Summary: Chiller 619 Kw, Dry Cooler 750 Kw
Deadline: 31 Jul 2026
Posting Date: 23 Jul 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 145792604
Document Ref. No.: UA-2026-07-22-9316819
Competition: ICB
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
CPV Classification
42511000 - Heat-exchange units and machinery for liquefying air or other gases
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
Technical task for the supply of the cold supply system of the technological process (chiller + dry cooler) 1. General provisions - Purpose: Providing the technological process of the enterprise with stable cold supply, taking into account the peak summer temperatures.- Required cooling capacity: At least 600 kW (under nominal conditions). The actual heat load of production is 431.6 kW. The presence of a power reserve is a mandatory requirement to compensate for the drop in productivity in the summer period.- Type of system: Water-water chiller of internal installation with an external dry cooler. Free cooling mode (Free Cooling) is not provided. 2. Requirements for a water-to-water chiller (Eraco EWW 6402 or equivalent) The equipment must meet the following minimum technical criteria:- Type of compressors: Semi-hermetic screw (Semi-Hermetic Screw). Offers based on sealed spiral (Scroll) compressors are not considered - Brand of compressors: FRASCOLD, Bitzer, Hanbell or equivalent of industrial class. - Quantity compressors: 2 pcs.- Performance regulation: Smooth / Stepless for maximum energy efficiency when working at partial load.- Evaporator heat exchanger (Water cooling): Shell & Tube.- Condenser heat exchanger (Glycol cooling): Shell & Tube.- Energy efficiency: Seasonal coefficient (SEPR) not lower than 5.5. EER at full load is not lower than 4.0.3. Requirements for a dry cooler / Drycooler (Eraco ER FCV 750 or equivalent) - Estimated thermal power: According to the selected chiller.- Estimated outside air temperature: The equipment must be guaranteed to remove condensation heat at an ambient temperature of +35°C.- Heat exchanger type: Microchannel (Microchannel) with aluminum finning (Al) to reduce the weight and volume of coolant filling. 4. Hydraulic circuits and coolants - Internal circuit (Evaporator - Workshop): Pure water (0% glycol). Temperature chart: input +12°C / output...
Name of material/service: Chiller 619 kW, Cooler dry 750 kW Submission of proposals lasts until: 22-07-2026, 11:33 a.m. to 31-07-2026, 20:30
Documents
Tender Notice