Procurement Summary
Country : USA
Summary : Boiler Useful Life Studies Hershel €Œwoody†Williams Vamc 581-24-3-507-0377
Deadline : 02 May 2024
Other Information
Notice Type : Tender
TOT Ref.No.: 100629134
Document Ref. No. : 36C24524Q0485
Competition : ICB
Financier : Self Financed
Purchaser Ownership : Public
Tender Value : Refer Document
Purchaser's Detail
Purchaser : VETERANS AFFAIRS, DEPARTMENT OF
Contracting Office Address : LINTHICUM, MD 21090
Primary Point of Contact : Bill Pratt
Billie.Pratt@va.gov
Phone Number 410-642-2411 ext. 22230
Fax Number Service Team 1
USA
Email :billie.pratt@va.gov
Tender Details
Description
SUMMARY:Department of Veterans Affairs, Veterans Health Administration, Network Contracting Office 5, is issuing this request for information/sources sought notice in order to identify vendors that are interested in and capable of performing a Condition Assessment Studies (Boiler Useful Life Studies) on Boilers #1, #2 and #3. Located at the Hershel Woody Williams VAMC located at 1540 Spring Valley Drive, Huntington WV, 25704. DESCRIPTION OF WORK: BACKGROUND The Huntington VAMC needs a vendor to perform Condition Assessment Studies (Boiler Useful Life Studies) for 3 (three) onsite boilers, which are in Bldg. 3. These studies determine overall condition and safety of the equipment. SCOPE OF WORK Vendor will provide all parts, labor, equipment, and material for inspection, examination, condition evaluation and reporting of three (3) onsite boilers: Boiler #1, Manufacturer: Johnston, Date: 1989, Model: PFTA 509, Type Fire Tube -4 Pass, Size: 400HP, Normal OP: 90psiBoiler #2 Manufacturer: Kewanee, Date: 1998, Model: H35-350-G02-LE-200 Type: Fire Tube -3Pass, Size: 350HP, Normal OP: 90psi.Boiler #3 Manufacturer: Kewanee, Date: 1998, Model: H35-300-G02-LE-200 Type: Fire Tube -3 Pass, Size: 300HP, Normal OP: 90psi.Tasks to be accomplished:1. Vendor will work with the Boiler Plant (Chris Lemon / 304-429-6755 x2360) to: Review plant safety regulations and lockout/tagout procedures Review equipment background information including safety relief valve data, manufacturers data sheets (if available), operating logs, maintenance and repair records, prior inspection data, and original or revised drawings.Comprehensive internal/external visual inspection of the boiler, boiler tubes, and casings/enclosureUltrasonic measurements of the shell and tubesheet thicknesses for the determination of estimated rates of material depletion and working pressure projectionsMagnetic Particle Testing weldments on each tube sheet will be examined for surface discontinuities that may b...
Active Contract Opportunity Notice ID 36C24524Q0485 Related Notice Department/Ind. Agency VETERANS AFFAIRS, DEPARTMENT OF Sub-tier VETERANS AFFAIRS, DEPARTMENT OF Office 245-NETWORK CONTRACT OFFICE 5 (36C245)
General Information
Contract Opportunity Type: Sources Sought (Original)
All Dates/Times are: (UTC-04:00) EASTERN STANDARD TIME, NEW YORK, USA
Original Published Date: Apr 29, 2024 12:04 pm EDT
Original Response Date: May 02, 2024 01:00 pm EDT
Inactive Policy: Manual
Original Inactive Date: Jun 01, 2024
Initiative: None
Classification
Original Set Aside:
Product Service Code: H335 - INSPECTION- SERVICE AND TRADE EQUIPMENT
NAICS Code: 541380 - Testing Laboratories and Services
Place of Performance: Department of Veterans Affairs Hershel “Woody†Williams VAMC Huntington, 25704
Documents
Tender Notice
36C24524Q0485.docx