The United States Coast Guard Surface Forces Logistics Center has a requirement and requesting quotations for the following part:
Item 1)
NSN: 4410-01-230-8024
BOILER, STEAM, 535 LBS/HOUR
USED WITH FORCED CIRCULATION HOT WATER HEATING SYSTEMS; SHIP-HEATERS ARE FULLY AUTOMATIC, OIL-FIRED, CENTRAL HEATING UNITS USED TO SUPPLY HOT WATER BY MEANS OF A CIRCULATING PUMP TO RADIATORS, CONVECTORS, OR OTHER HEATING ELEMENTS.
BOILER: MARINE WELDED CONSTRUCTION; MARINE HEATING OPERATION AT 30 PSI MAXIMUM HOT WATER PRESSURE OR 15 PSI MAXIMUM STEAM PRESSURE.
OIL BURNER: FULLY AUTOMATIC, HIGH PRESSURE ATOMIZING TYPE; SELF-PRIMING FUEL PUMP DRAWS OIL FROM STORAGE TANK; MECHANICAL SHUT-OFF VALVE IN FUEL PUMP W/ ELECTRIC OIL
SHUT-OFF; IGNITION IS AUTOMATIC ELECTRIC SPARK.
FIRE RATE (GPH): 8.00 MAX, 4.00 NORMAL
BTU/HR. OUPUT RATING: 840, 000 MAX, ~ 420, 000 NORMAL
WATER RADIATION, SQ. FT: 5600 MAX, ~ 2800 NORMAL
STEAM RADIATION, SQ. FT: 3;500 MAX, ~ 1750 NORMAL
GALLONS/HR. 100 DEGREES F RISE: 990 MAX, ~ 495 NORMAL
DRY WT: ~ 1885LBS
BURNER MOTOR: ~ 1/2HP, NOZZLES 3.00 60 (DEGREE) A
HEIGHT: ~ 77 3/4"
WIDTH: ~ 32"
CONFIGURE BOILER IN ACCORDANCE WITH WAY-WOLFF DWG H-581, UTILIZING THE MCDONNELLMILLER M93 FLOAT SWITCH AND THE WARRICK 3C2A6-25 INLG LOW WATER PROBE. SHALL BE EQUIPPED WITH: AIR INLET P/N M-260, SCANNER MOUNTING PLATE P/N M-476-1, HONEYWELL C7915A FLAME DETECTOR AND C7848A AMPLIFIER ARE P/N M-489-2, SIGHT GLASS P/N M 432, SIGHT GLASS FITTINGS ML150. SHALL BE COMPATIBLE TO RE-UTILIZE EXISTING BULKHEADMOUNTED
ELECTRICAL CONTROLLER AS PER DRAWING 618WMEC517-001.
EACH ITEM MUST BE INDIVIDUALLY PAKAGED AND MARKED
+
MFG: SELAS HEAT TECHNOLOGY COMPANY LLC
PN: 5848-14E-STEAM
QTY: 3 EA
*****STANDARD COMMERCIAL PACKAGING IS UNACCEPTABLE, IF YOU CANNOT MEET THE COAST GUARDS PACKAGING REQUIREMENTS YOUR QUOTE WILL NOT BE ACCEPTED. *****
Brand Name part is mandatory to be considered for award, offers of “equal” produc...
Notice ID: 70z08026qro008
Department/Ind. Agency: homeland security, department of
Original Set Aside: total small business set-aside (far 19.5)
Sub-tier: us coast guard
Office: sflc procurement branch 1(00080)
Product Service Code: 4410 - industrial boilers
NAICS Code: 333414 - Heating Equipment (except Warm Air Furnaces) Manufacturing
Inactive Dates: mar 26, 2026
Inactive Policy: 15 days after date offers due