Description
National Institute of Standards and Technology (NIST)
Acquisition Management Division,
100 Bureau Drive, Mail Stop 1640,
Gaithersburg, MD, 20899-1640
Sources Sought Notice NIST-MML-25-SS20
Title: Benchtop Thermogravimetric Analyzer (TGA)/Differential Scanning Calorimetry (DSC)
This is a Sources Sought Notice ONLY. Requests for copies of a solicitation will not receive a response.
This Notice is for planning purposes only and is not a Request for Proposal or Request for Quotation or an obligation on the part of the National Institute of Standards and Technology (NIST) for conducting a follow-on acquisition. NIST does not intend to award a contract on the basis of this Notice, or otherwise pay for the information requested. No entitlement or payment of direct or indirect costs or charges by NIST will arise as a result of submission of responses to this Notice and NIST use of such information. This Notice will also assist the Government in determining if there are any domestic manufactured end product sources for the project title.
NO SOLICITATION DOCUMENTS ExIST AT THIS TIME.
Requirement:
NIST is seeking information on contractors who can provide the following:
A Benchtop Thermogravimetric Analyzer (TGA)/Differential Scanning Calorimetry (DSC) with the following performance requirements.
The systems furnace is capable of operation up to 1750 oC or in an oxidizing (air) atmosphere. The system must accommodate heating rates up to 50 oC/min. The furnace must be equipped with MoSi2 type heating elements The furnace cannot contain graphite components. The TGA/DSC system must accommodate reactive gas environments (gas mixtures with 5% H2 at most) with high concentrations of water vapor - this includes the ability to heat the gas delivery tubing to the furnace to prevent condensation. Minimum resolution of the TGA system of 0.1 mg. The TGA/DSC analyzer sample holders must accommodate samples with a volum...
Active Contract Opportunity
Notice ID : NIST-MML-25-SS20
Related Notice
Department/Ind. Agency : COMMERCE, DEPARTMENT OF
Sub-tier : NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY
Office: DEPT OF COMMERCE NIST
General Information
Contract Opportunity Type: Sources Sought (Original)
Original Published Date: Jun 24, 2025 11:14 am EDT
Original Response Date: Jul 07, 2025 04:00 pm EDT
Inactive Policy: Manual
Original Inactive Date: Jul 08, 2025
Initiative: None
Classification
Original Set Aside:
Product Service Code:
NAICS Code: 334516 - Analytical Laboratory Instrument Manufacturing
Place of Performance: Gaithersburg, MD 20899 USA
Documents
Tender Notice