Cross Icon
Cross Icon

630A426401 Mri Ahu Modification Tender in USA - 145897791

The VETERANS AFFAIRS, DEPARTMENT OF has issued a Tender notice for the procurement of a 630A426401 Mri Ahu Modification in the USA. This Tender notice was published on 25 Jul 2026 and is scheduled to close on 07 Aug 2026, with an estimated Tender value of Refer Document. Interested bidders can access detailed Tender information, eligibility criteria, and complete bidding documents by referencing TOT Ref No. 145897791, while the tender notice number is 36C24226R0060 and Registering on the platform.

Expired Tender

Procurement Summary

Country: USA

Summary: 630A426401 Mri Ahu Modification

Deadline: 07 Aug 2026

Posting Date: 25 Jul 2026

Other Information

Notice Type: Tender

TOT Ref.No.: 145897791

Document Ref. No.: 36C24226R0060

Competition: ICB

Financier: Self Financed

Purchaser Ownership: Public

Tender Value: Refer Document

Purchaser's Detail

Name: Login to see tender_details

Address: Login to see tender_details

Email: Login to see tender_details

Login to see details

Tender Details

36C24226R0060
Amendment 3
630A4-26-401 MRI AHU Modification
6. Per our teams meeting this morning, please see below RFI's;
There are 3 potential options for the MRI chiller:
Air cooled package at grade with glycol and pump package.
Air cooled package at grade using glycol but also using a plate and frame heat exchanger to separate the glycol from the clear water.
Air cooled split chiller with outdoor condenser and indoor evaporator using clear water only.
Does The VA have a preference for which system works better for them?
The scope of work calls for an inline pump to serve the fan coil units. Can the VA share the reason for these extra pumps as series pumping can present issues. If the additional head is included in the new chiller pumps does that suffice?
There are 6 new fan coil units called for in the corridor. This is 9 tons of cooling. Does the corridor have that kind of a load? Typically, corridors are only lighting and a few transient people. Also, if 9 tons is used for fan coil units, is 21 tons sufficient for the MRI Load?
COR answer(s):
It appears that Option 2 may be the more effective choice; however, as this is a design-build project, we rely on the A/E team s expertise to design the system in accordance with VA requirements and specifications.
Accordingly, a series pump configuration is not considered an acceptable design.
The A/E team should perform its own heat load calculation for the corridor to determine the required cooling capacity. The VA has provided only general information; it is the contractor s design team s responsibility to determine the actual requirements and verify whether the chiller recommended by the VA is sufficient.
Notice ID: 36c24226r0060

Department/Ind. Agency: veterans affairs, department of

Sub-tier: veterans affairs, department of

Office: 242-network contract office 02 (36c242)

Product Service Code: y1da - construction of hospitals and infirmaries

NAICS Code: 236220 - Commercial and Institutional Building Construction

Inactive Dates: sep 06, 2026

Inactive Policy: manual

Documents

 Tender Notice

Documents.zip


Corresponding Contract Award Notice

No Contract Award Notice found for this tender. Please try using the Contract Award Search Page.


Request Demo
GiZ Tenders India

Procurement Documents for USA

Access a comprehensive library of standard procurement documents specific to USA. Here, you'll find all the essential forms, guidelines, and templates required for tender applications and submissions in USA

Explore Procurement Documents for USA


Want To Bid in This Tender?

Get Local Agent Support in USA and 60 More Countries.

View All The Services


View Tenders By


Publish Tenders


Have Any Dispute With The Purchaser?