Procurement Summary
Country : USA
Summary : 528A6-25-612 Seeking Sources Two Air-Cooled Chillers Bath VA Medical Center
Deadline : 22 May 2025
Other Information
Notice Type : Tender
TOT Ref.No.: 119182459
Document Ref. No. : 36C24225Q0625
Financier : Self Financed
Purchaser Ownership : Public
Tender Value : Refer Document
Purchaser's Detail
Name :Login to see tender_details
Address : Login to see tender_details
Email : Login to see tender_details
Login to see detailsTender Details
Description
Statement of WorkPurchasing 2 Air-Cooled Chillers for B 78 CLC528A6-25-612Scope:The selected Contractor is to supply two 60-ton, air-cooled, scroll-type chillers for Building 78 (CLC) and two chilled water pumps to replace the existing equipment. Installation work will be performed in-house by VA Shop personnel at the designated job site. The project site is located at the Veterans Affairs Medical Facility in Bath, NY. The provided equipment must meet the specified capacity requirements outlined in the project specification package. The Contractor is responsible for delivering the specified units to the Bath VA Medical Center at 76 Veterans Ave, Bath, NY 14810. VA trades personnel will handle unloading, positioning, and connecting the units to the existing system. The Contractor shall then perform testing, commissioning, and setup of the units in accordance with the manufacturer s recommendations and the project specifications, including programming the units into the existing Building Automation System.Contractor Responsibilities:Contractor must Furnish TWO nominal 60 Ton Air- Cooled Scroll Chillers. Basis of Design Trane CGAM series. Contractor must furnish TWO chilled water pumps. Basis of design B&G e-1510 Base Mounted Pump Series, 2AD 2HP 230/460 1800RPM, the size must be at 132 gpm flow rate and 35 Ft H2o Head loss. Contractor to perform start up must ensure operations and proper integration to existing Trane Tracer Ensemble building management system.Vender must ensure Unit is fully compatible, able to integrate without workarounds and 100% back-net compliant to communicate with Trane Tracer Ensemble building management system. The contractor must deliver the equipment no later than December 31st, 2025.Contractor must follow all the federal regulations and the national and local safety codes while performing any work on the VA property. The Contractor shall coordinate with the COR and the VA utility shops; all the onsite work required for this...
Active Contract Opportunity
Notice ID : 36C24225Q0625
Related Notice
Department/Ind. Agency : VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier : VETERANS AFFAIRS, DEPARTMENT OF
Office: 242-NETWORK CONTRACT OFFICE 02 (36C242)
General Information
Contract Opportunity Type: Sources Sought (Original)
Original Published Date: May 14, 2025 09:43 am EDT
Original Response Date: May 22, 2025 04:00 pm EDT
Inactive Policy: Manual
Original Inactive Date: Jul 06, 2025
Initiative: None
Classification
Original Set Aside:
Product Service Code: 4130 - REFRIGERATION AND AIR CONDITIONING COMPONENTS
NAICS Code: 333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
Place of Performance: Department of Veterans Affairs Bath VA Medical Center Bath, NY 14810 USA
Documents
Tender Notice
36C24225Q0625.docx