36C25525Q0411 | 5 Year ARC FLASH STUDY | Wichita VAMC Tender, USA - 120692382

VETERANS AFFAIRS, DEPARTMENT OF has floated a tender for 36C25525Q0411 | 5 Year ARC FLASH STUDY | Wichita VAMC. The project location is USA and the tender is closing on 12 Jun 2025. The tender notice number is 36C25525Q0411, while the TOT Ref Number is 120692382. Bidders can have further information about the Tender and can request the complete Tender document by Registering on the site.

Expired Tender

Procurement Summary

Country : USA

Summary : 36C25525Q0411 | 5 Year ARC FLASH STUDY | Wichita VAMC

Deadline : 12 Jun 2025

Other Information

Notice Type : Tender

TOT Ref.No.: 120692382

Document Ref. No. : 36C25525Q0411

Financier : Self Financed

Purchaser Ownership : Public

Tender Value : Refer Document

Purchaser's Detail

Name :Login to see tender_details

Address : Login to see tender_details

Email : Login to see tender_details

Login to see details

Tender Details

Description

D.1 Statement of Work (SOW)I. BACKGROUND1. The contractor will provide all tools, materials, labor, supervision, and test equipment to perform the 5-Year Arc Flash Safety Service Testing at the Robert J. Dole VA Medical Center at 5500 E. Kellogg Ave. Wichita, Ks 67218. The Arc Flash Safety Service will identify electrical system hazards and provide proper labeling and recommendations for remediation per the National Fire Protection Association (NFPA) and the Institute of Electrical and Electronics Engineers (IEEE) safety standards and industry practices. II. SCOPE2. Understanding and Assumptions(a) This Statement of Work defines the scope of the Arc Flash Safety Service that a vendor will provide, which will include the following:(1) The vendor will gather data relevant to arc flash safety through a review of information provided by the medical center and collected by the vendor during an on-site assessment.(2) Based on the data collected, the vendor will perform an initial arc flash analysis per industry standards to identify arc flash hazards.(3) The vendor will review the findings with the Medical Center.(4) The vendor will provide the Medical Center with one-line diagrams of the power system, recommendations for mitigation of arc flash hazards, and arc flash safety labeling.(5) The vendor's personnel will apply the arc flash labeling to the relevant equipment.(6) The vendor can begin the work within four weeks or less of an indication that we will receive the project. Vendors anticipate completion of the base arc flash study within ten weeks after the completion of the field investigation.(b) The following count of electrical equipment is summarized based on the one-line diagrams provided. (1) Two 12.47-kilovolt utility services (2) One 12.47-kilovolt double-ended substation (3) Ten 12.47-kilovolt selector switches (4) Three 12.47-kilovolt switchgear (5) Eight 12.47-480V transformers (6) Seven 12.47-208V transformers (7) Four 12.47-240V transform...
Active Contract Opportunity
Notice ID : 36C25525Q0411
Related Notice : 36C25525Q0411
Department/Ind. Agency : VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier : VETERANS AFFAIRS, DEPARTMENT OF
Office: 255-NETWORK CONTRACT OFFICE 15 (36C255)
General Information
Contract Opportunity Type: Solicitation (Original)
Original Published Date: Jun 10, 2025 03:07 pm CDT
Original Date Offers Due: Jun 12, 2025 11:00 am CDT
Inactive Policy: Manual
Original Inactive Date: Jun 17, 2025
Initiative: None

Classification
Original Set Aside:
Product Service Code: H999 - OTHER QC/TEST/INSPECT- MISCELLANEOUS
NAICS Code: 541330 - Engineering Services

Place of Performance:

Documents

 Tender Notice

36C25525Q0411.docx


Procurement Documents for USA

Access a comprehensive library of standard procurement documents specific to USA. Here, you'll find all the essential forms, guidelines, and templates required for tender applications and submissions in USA

Explore Procurement Documents for USA


Want To Bid in This Tender?

Get Local Agent Support in USA and 60 More Countries.

View All The Services


View Tenders By


Publish Tenders


Have Any Dispute With The Purchaser?