CITY OF GENERAL SANTOS , SOUTH COTABATO has floated a tender for 24Cb-Gsc-235 Purchase of Automated Earthquake Sensor. The project location is Philippines and the tender is closing on 23 Apr 2024. The tender notice number is 24CB-GSC-235 PURCHASE OF AUTOMATED EARTHQUAKE SENS, while the TOT Ref Number is 99641457. Bidders can have further information about the Tender and can request the complete Tender document by Registering on the site.

Expired Tender

Procurement Summary

Country : Philippines

Summary : 24Cb-Gsc-235 Purchase of Automated Earthquake Sensor

Deadline : 23 Apr 2024

Other Information

Notice Type : Tender

TOT Ref.No.: 99641457

Document Ref. No. : 24CB-GSC-235 PURCHASE OF AUTOMATED EARTHQUAKE SENS

Competition : ICB

Financier : Self Financed

Purchaser Ownership : Public

Tender Value : PHP 3000000.00

Purchaser's Detail

Purchaser : CITY OF GENERAL SANTOS, SOUTH COTABATO
Marites M. Sevilla
BAC-Sec Head
Investment Action Center
4th floor
General Santos City
South Cotabato
Philippines 9500
63-83-5529435
63-83-3010553
Philippines
Email :bac.gsc2018@gmail.com

Tender Details

Tender are invited for 24CB-GSC-235 PURCHASE OF AUTOMATED EARTHQUAKE SENSOR

Procurement Mode : Public Bidding

Classification : Goods

Category : Safety and Occupational Products

Contract Duration : 60 Day/s

Budget for the Contract : PHP 3, 000, 000.00

Area of Delivery : South Cotabato

Description : Republic of the Philippines

Local Government Unit of General Santos City

BIDS AND AWARDS COMMITTEE

GOODS AND CONSULTANCY SERVICES

City Hall, General Santos City

Total

DESCRIPTION OF ARTICLES

ITEM

NO.

1.

SENSOR EQUIPMENT

AUTOMATED EARTHQUAKE SENSOR

TECHNICAL SPECIFICATIONS:

DATA ACQUISITION

GENERAL PRINCIPLE: CONTINUOUS REAL TIME MODE ACQUISITION

ADC RESOLUTION: 16 BITS

SAMPLING RATE: FROM 0.01 TO 1500 SPS

MAX. POSSIBLE SAMPLING RATE: 200 KSPS

NUMBER OF CHANNELS: 16 CHANNELS (ACQUISITION), 7 DIGITAL OUTPUTS (CONTROL AND ALARMS), 1 VOICE OUTPUT.

CHANNEL SKEW: SIMULTANEOUS SAMPLING ON ALL INPUT CHANNELS

DATA FILTER: ANTI ALIASING FILTERS

TRIGGER FILTER: DIGITAL IIR FILTER: 0.5 - 15 HZ BAND PASS (STRONG MOTION APPLICATIONS)



TRIGGERING MECHANISM

LEVEL: 0.1 % TO 100 % F.S.

SELECTION: INDEPENDENT TRIGGER PER CHANNEL

POST TRIGGER: 10 SECONDS PRIOR TO EVENT AND 10 SECONDS POST EVENT DATA IS AVAILABLE AT MAXIMUM SAMPLING RATE

POST TRIGGER AUTOMATION: AUTOMATIC SELF ADJUSTMENT FROM 20 TIMES TO 1000 TIMES DEPENDING ON EVENT MAGNITUDE

TRIGGER DELA...

Documents

 Tender Notice