Procurement Summary
Country : USA
Summary : - 623 (Activation NCO19LAB) Biofire FilmArray Torch System, PKG 36 CHIP-IN, SEPG 491996 EER 257002
Deadline : 07 Jul 2025
Other Information
Notice Type : Tender
TOT Ref.No.: 121731661
Document Ref. No. : 36C25925Q0579
Financier : Self Financed
Purchaser Ownership : Public
Tender Value : Refer Document
Purchaser's Detail
Name :Login to see tender_details
Address : Login to see tender_details
Email : Login to see tender_details
Login to see detailsTender Details
Description
DESCRIPTIONREQUEST FOR INFORMATION / SOURCES SOUGHT INQUIRYTHIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR PROPOSAL. The Department of Veterans Affairs Network Contracting Office (NCO) 19, Rocky Mountain Acquisition Center (RMAC) is seeking information and sources that can provide Activation Biofire FilmArray 4 Torch System, Brand Name or Equal To for James Mountain Inhofe VA Medical Center 440 S. Houston Avenue Tulsa, OK 74127.The Equal To offer must meet the following salient characteristics:System Type: Automated In Vitro Diagnostic DevicePerformance Features: One Hour Sample Run Time System Base with Touch Screen and Barcode Scanner Automatic analysis with end-of-run interpretive reportsOptics and Imaging: Single color optics module: 475nm excitation, 545nm emission, and sensor imagingScalability and Throughput: Scalable configuration allows customized throughput Compatible with six syndromic BIOFIRE® FILMARRAY® Panels. Reduced footprint provides up to six times the throughput per square foot of laboratory bench spaceData management: Automation includes LIS connectivity and random-access operationTemperature Control: Operating temperature 15°C to 30°C Peltier devices: Ambient to 100°C Ramp rate from 0.1 0.5°C /sec on meltOperations Specification: 15°C to 30°C @ 20 to 80% relative humidity (non-condensing) -16m to 3048m Indoor use onlySystem Interface/Hardware: Capacitive Touch Screen Interface 512 GB Hard DriveGB RAMCPU Dimensions and Weight: Dimensions System Base: 18 x 29 x 11.5 in (45.8 x 73.7 x 29.2 cm) (W x D x H) Module Height 4.5 in (11.4 cm) Max Height 34 in (86.4 cm) max height Weight: (Maximum total) Approximately 268 lbs (121.6 kg) System Base 36 lbs (16.3 kg) Modules 15 lbs (6.8 kg) each Duplex (Module enclosure) 6.5 lbs (
3 kg) each QTY: 1The contractor must provide all parts required to meet the salient characteristics required:One (1) Activation Biofire FilmArray 4 Torch System, Brand Name or Equal To- P...
Active Contract Opportunity
Notice ID : 36C25925Q0579
Related Notice
Department/Ind. Agency : VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier : VETERANS AFFAIRS, DEPARTMENT OF
Office: NETWORK CONTRACT OFFICE 19 (36C259)
General Information
Contract Opportunity Type: Sources Sought (Original)
Original Published Date: Jun 27, 2025 10:20 am MDT
Original Response Date: Jul 07, 2025 04:00 pm MDT
Inactive Policy: Manual
Original Inactive Date: Aug 06, 2025
Initiative: None
Classification
Original Set Aside:
Product Service Code: 6630 - CHEMICAL ANALYSIS INSTRUMENTS
NAICS Code: 334516 - Analytical Laboratory Instrument Manufacturing
Place of Performance: Department of Veterans Affairs James Mountain Inhofe VA Medical Center Tulsa, OK 74127 USA
Documents
Tender Notice
36C25925Q0579.docx