Procurement Summary
Country : Philippines
Summary : Supply and Delivery of Hospital/Medical Equipment
Deadline : 07 Aug 2018
Other Information
Notice Type : Tender
TOT Ref.No.: 25145058
Document Ref. No. : 2018-devmh-104
Competition : ICB
Financier : Self Financed
Purchaser Ownership : -
Tender Value : Refer Document
Purchaser's Detail
Purchaser : DON EMILIO DEL VALLE MEMORIAL HOSPITAL
Agripina F Ceremones
BAC Secretariat
Bood,
Ubay
Bohol
Philippines 6315
63-38-5188309
63-38-5188309
devmh.procurement@gmail.com
Philippines
Email :devmh.procurement@gmail.com
Tender Details
Supply and Delivery of Hospital/Medical Equipment
Stock/ Unit Item Description Quantity Estimated Total Cost
Property No. Unit Cost
1 unit 2D DIGITAL MAMMOGRAPHY MACHINE 1 14, 800, 000.00 14, 800, 000.00
Description:
A device intended for mammography (breast) procedures and
provide diagnostic images and should feature a short term
examination cycle and image display time. The image detector
section of the exposure unit is equipped with a direct convesion
panel detector and uses a proprietary panel to acquire high
quality images with a high resolution and low level of noise.
The unit should be tomosynthesis ready and upgradeable.
The unit should also be Stereotatic Biopsy ready and upgradeable
2D biopsy applicable.
X-ray Generator and X-ray Tube:
a. Should be high frequency and preferably inverter type at least 5kW
b. Tube voltage range: 22kV to 50kV in (1kV interval)
c. mAs setting: 1mAs to 600mAs with precision setting at +/- 10% + 2mAs
d. Tube current: large focus at least 200mA small focus at least 50mA
e. two focal spot size: large at 0.3 and small at 0.1
f. anode material: Tungsten
g. Anode heat storage capacity and dissipation: 300, 000 HU at 60, 000HU/min
h. Tube filter: 0.63mm Berrylium
i. X-ray generator filter: 0.7mm Aluminum
j. Tube assembly heat storage capacity: 500, 000 HU
k. Anode angulation: large at 16 degrees and small at 10 degrees
l. Air tube cooling system
m. Swivel arm and rotation: vertical travel 30in to 50in and +/- 180 to 190degrees.
X-ray Detector Sensor:
a. Panel detector material: a-Se
b. Surface image area: not less than 23in x 30in range
c. Pixel size: less than 100microns. The lesser, the better the image
d. Output pixel: at least 4000 to 5000 range. The more, the better the image
e. Output gradation: 10bits to 16bits range
Unit/Ganty Discriptions:
a. Compression: manual/automatic with foot pedal compressions. Breast
compression should be motorized but can be manually controlled for
small compression increments.
b. Face protective shield
c. Automatic collimator-paddle recognition.
d. Motorized ganty rotation
e. 24cm x 30cm and 18cm x 24cm
f. Spot and magnification compression plates
g. Compression plate holder and rests.
Image Storage and Acquisition:
(Radiologic Technologist's Area)
a. CPU: Intel 3.5GHz or higher speed.
RAM: 8GB or higher.
HDD: SATA 500GB or higher
One (1) 2MP medical grade Monitor PC 20inches or larger
OS: Windows 10 Pro or latest compatible for medical set-up.
Compatible mouse, keyboard, AVR, UPS.
Patient directory for patient data and search.
Patient annotation and orientation label.
Length angle and measurement
Zoom and pan image
Compatible photoprinter
CD/DVD writer for Radiologist's Area.
b. CPU: Intel 3.5GHz or higher
RAM: 16GB or higher
HDD: SATA 2TB or higher and separate drive 2000GB or
lower for operating system application only.
Two (2) 5MP medical grade monitor pc 20inches or larger
OS: Windows 10 Pro or latest compatible for medical set-up
Compatible mouse, keyboard, AVR, Ups.
One (1) 17inch standard PC monitor for reporting encoding
One (1) standard printer CISS ink system for results printing
DICOM Connectivity:
a. It shall have full DICOM capabilities (storage, query/retrive,
work list, print, MPPS)
b. It shall have embedded virus protection solution.
c. Compatible to PACS and RIS workflow modality, CAD, DICOM printer.
Service Center:
a. There should be a local service center with engineer immediately for
troubleshooting / preventive maintenance or within 24-48 hours time
expectation for problems cannot be settled on phone instructions.
b. Valid and Traceable Calibration Certificate.
c. Mammography phantom with QC Software.
Warranty:
a. One year standard comprehensive warranty with
additional 2 years service warranty.
b. Preventive maintenance every quarter within the warranty period.
c. Operators manual
d. Service manual
e. Certification on availability of parts within 10 years
f. Certification that the brand will be still in the market within 10 years.
Training and Accessories:
a. Onsite and Offsite Operators and Technical applications training
for 1 RadTeck and Biomed.
b. Lead gowns with thyroid shield and lead googles.
c. Lead barrier for the Rad Tech
d. Can provide 2HP split type aircondition system (inverter)
Power Supply:
Single phase, 220V-240V AC, 60Hz with UPS.
Pre-bid Conference
DateTimeVenue
26/07/20182:00 PMDEVMH Conference Room, Admin. bldg.
Closing Date : 2018-08-07
Documents
Tender Notice