BENGUET GENERAL HOSPITAL has floated a tender for Purchase of Various Medical Equipment ( 2018-11-172). The project location is Philippines and the tender is closing on 22 Feb 2019. The tender notice number is 2018-11-172, while the TOT Ref Number is 30734942. Bidders can have further information about the Tender and can request the complete Tender document by Registering on the site.

Expired Tender

Procurement Summary

Country : Philippines

Summary : Purchase of Various Medical Equipment ( 2018-11-172)

Deadline : 22 Feb 2019

Other Information

Notice Type : Tender

TOT Ref.No.: 30734942

Document Ref. No. : 2018-11-172

Competition : ICB

Financier : Self Financed

Purchaser Ownership : -

Tender Value : Refer Document

Purchaser's Detail

Purchaser : BENGUET GENERAL HOSPITAL
Manuel, Jr. A Palasi
BAC Secretariat Vice Chairman
Km. 5, Pico,
La Trinidad
Benguet
Philippines 2601
63-074-4224722 Ext.1651
63-074-4225506
beghbac@benguet.gov.ph
Philippines
Email :beghbac@benguet.gov.ph

Tender Details

Purchase of Various Medical Equipment ( 2018-11-172)

ITEM QTY UNIT ITEM DESCRIPTION STOCK ESTIMATED ESTIMATED

NO. OF ISSUE NO. UNIT COST COST

1 1 UNIT Anesthesia Multiparameter Machine 300, 000.00 300, 000.00

* 10 - 15 inch high resolution, easy to discern and read display, user friendly configuration, with minimal hassle in inputing necessary parameters

* Rechargeable lithium battery with 120 to 150 min. battery standby capability

* Power supply voltage AC 100-240V 50/60 Hz

* Power input of 85a and with built in fuse

* Power plug compatible with the existing 3 pronged electrical sockets of the OR

* Standard configuration :

NIBP

: adult, pediatric, neonate configurations

":automatic oscillometry with measurement range of 10 to 250 mmHg

"

":manual and automatic interval settings of continuous, 1, 3, 4, 10, 15, 30 and 60 minutes

"

: NIBP cable length of 3 - 5 meters

ECG

: 3 to 12 lead capability

: Standard arrhythmia detection

: Capable of Lead selection I, II, III and V1 - V6

: ECG cable length of 3 - 5 meters

sPO2

": Capable of showing functional oxygen saturation

from 0 to 100 % with accuracy of +/- 2 digits

and updating frequency with each heartbeat

"

: Capable of functioning in low perfusion settings

: sPO2 cable length of 3 - 5 meters

Resp

: range of 0 - 150 rpm with accuracy of +/- 2 rpm

HR

: range of 10 - 300 bpm

Temp

: range of 25.0oC - 50oC

: temp cable length of 3 - 5 meters

* Additional configuration

CO2 (side/mainstream)

IBP (two channel and reusable cables)

* Able to store at least 8 hours of continuous data

"* With flashing and adequate, adujustable audio alarms for all

parameters

"

* Optional printer capability

* Dimensions = 300 - 400 mm x 320 - 340 mm x 140 - 170 mm

* Weight = 4 - 6 kgs



***Additional terms of acceptability :

1. The machine must come from a company that is ISO 9001 : 2000 certified and has passed CE and IEC specifications

2. Supplier must be capable of providing 24 - 48 hours response time should breakdowns occur.

3. The Machine must be supplied with it-s own Universal Power Surge protector.

4. The Supplier must provide a portable and movable stand specific for the monitor.

5. Supplier must provide quarterly to semi - annual preventive maintenance for at least 2 years, without cost to the hospital and renewable for 2 years thereafter.

6. Supplier must bind itself to service the equipment within a minimum warranty period of 2 years.

7. Supplier must either be the exclusive distributor or authorized distributor of the principal company of the equipment and the necessary consumables in the Philippines.

8. The NIBP cable shall be compatible with the existing BP cuffs of the hospital.

9. The pulse oximeter cable of the machine shall be compatible with the existing pulse oximeter probes of the hospital.

10. Supplier must upgrade the equipment free of charge provided the equipment is under warranty.

11. The company must have provided on-hands demonstration of the unit for 1 week to the concerned end - user.

7 2 UNIT Air / Oxygen Blender (for NICU) 100, 000.00 200, 000.00

*Specification

"Dimensions:

(without fittings)" Depth: 4.92- (12.5 cm) Width: 2.25- (5.7 cm) Height: 4.10- (10.4 cm)

Weight: 3.4 lbs (1.5 kg)

Operating 59AF to 104AF (15AC to 40AC)

Temperature: A+/-3% of full scale

FiO2 Accuracy: 13-25 psi (0.9-1.7 bar)

Bypass Alarm Activation: 13-25 psi (0.9-1.7 bar)

Primary Outlet Flow Range: 15-120 lpm

Auxiliary Outlet Flow Range: 2-100 lpm

Bleed Flow: at 50 psi (3.4 bar) 13 lpm or less

Maximum Combined Flow: (all outlets) a‰120 lpm

No. of Primary Outlet Ports: 3

No. of Auxiliary Outlet Ports 1

*Accessories:

"Oxygen Monitor (Coil Cable, Diverter,

Sensor, T Piece and 4 AA batteries)"

Condensation Trap w/DISS Fitting

Wall Mount

Pole Mount

Flowmeters

Hose Assemblies

* Additional terms of acceptance:

1. The supplier must provide a minimum of 2 years warranty

8 1 UNIT Electric Breast Pump, hospital gr...