CLARK DEVELOPMENT CORPORATION has floated a tender for Installation of Four (4) Recovered Wall Mounted Aircon Units. The project location is Philippines and the tender is closing on 28 Mar 2019. The tender notice number is 1902040, while the TOT Ref Number is 31770562. Bidders can have further information about the Tender and can request the complete Tender document by Registering on the site.

Expired Tender

Procurement Summary

Country : Philippines

Summary : Installation of Four (4) Recovered Wall Mounted Aircon Units

Deadline : 28 Mar 2019

Other Information

Notice Type : Tender

TOT Ref.No.: 31770562

Document Ref. No. : 1902040

Competition : ICB

Financier : Self Financed

Purchaser Ownership : -

Tender Value : Refer Document

Purchaser's Detail

Purchaser : CLARK DEVELOPMENT CORPORATION
Cornelio P Velasco
Admin Officer II
CDC Corporate Buildings, E. Quirino Ave., CFZ
Angeles City
Pampanga
Philippines 2023
63-45-5999000 Ext.785

corneliovelasco@clark.com.ph
Philippines
Email :corneliovelasco@clark.com.ph

Tender Details

Installation of Four (4) Recovered Wall Mounted Aircon Units

CLARK DEVELOPMENT CORPORATION

Clark Freeport Zone, Philippines



REQUEST FOR QUOTATION



The Clark Development Corporation, through its Purchasing Division(PD), invites suppliers/

manufacturers/contractors to send proposal for the hereunder project:





Name of Project : Supply of Labor, Materials and Services of Contractors



Location : Clark Freeport Zone, Philippines

Brief Description : Installation of Four (4) Recovered Wall Mounted Aircon

Units (2 units- 3.0HP capacity @ 1st floor and 2 units-

2.5HP capacity @ 2nd floor) for Bldg. 2515B

For inquires contact: Cornelio Velasco (09175848511/ 0455993536)



Approved Budget : Php 90, 000.00 (VAT Exclusive)

Delivery Schedule : 7 days





Prospective suppliers/manufacturers/contractors should have experience in undertaking similar

with the proposed project. Post-qualification of the lowest calculated bid shall be conducted.





All procedures shall be governed by the pertinent provisions under Section 53.9 of R.A. 9184 and its

Implementing Rules and Regulation (IRR) and guidelines on Small Value Procurement (GPPB

Resolution 09-2009 dated November 23, 2009).





The prospective suppliers/manufacturers/contractors must submit their proposal in a sealed

envelope on or before March 28, 2019 at the address given below:





Purchasing Division

Clark Development Corporation

Bldg. 2121 C.P. Garcia Street,

CDC Corporate Center, Clark Freeport Zone

Philippines 2023

Tel. Nos. (045) 599-9000 local 782

E-mail : lanceljohnlagman@clark.com.ph

Website : www.clark.com.ph





CDC assumes no responsibilty whatsoever to compensate or indemnify bidders for any expenses

incurred in the preparation of the bid. CDC reserves the right to accept or reject any bid, and to

annul the bidding process and reject all bids at any time prior to contract award, without thereby

incurring any liability to the affected bidder or bidders.





Approved by:



***original signed***

RODGARDO M. DEANG

PD Manager





Line Items

Item No.Product/Service NameDescriptionQuantityUOMBudget (PHP)

1Air Conditioning Maintenance ServiceInstallation of Four (4) Recovered Wall Mounted Aircon Units1Lot90, 000.00





Other Information

1 LOT Supply of Labor, Materials & Services of Contractors

Installation of Four (4) Recovered Wall Mounted Aircon

Units (2 units- 3.0HP capacity @ 1st floor and 2 units-

2.5HP capacity @ 2nd floor) for Bldg. 2515B

Scope of Work:

A. 2 units- 3.0HP capacity @ 1st floor

1. Pull out 2units floor mounted aircons for CDC warehouse

2. General cleaning of aircon units

3. Rehabilitation of aircon units (AHU and ACCU) which

includes flushing

4. Installation aircon units at designated area

5. Installation of refrigerant piping (25ft each) 5/8 diameter

x 3/8 diameter with 3/4 thick installation

6. Installation of electrical wirings #12 THHN (30ft each)

7. Provision of service circuit breaker 30amps with NEMA

3R enclosure

8. Installation of feeder line #10 THHN (30ft each)

9. Install condensate drain

10. Leak detection and vacuuming of system

11. Charging of Refrigerant 22

12. Testing

B. 2 units- 2.5HP capacity @ 2nd floor

1. Pull out 2units floor mounted aircons for CDC warehouse

2. General cleaning of aircon units

3. Rehabilitation of aircon units (AHU and ACCU) which

includes flushing

4. Installation aircon units at designated area

5. Installation of refrigerant piping (25ft each) 5/8 diameter

x 3/8 diameter with 3/4 thick installation

6. Installation of electrical wirings #12 THHN (30ft each)

7. Provision of service circuit breaker 20amps with NEMA

3R enclosure

8. Installation of feeder line #10 THHN (20ft each)

9. Install condensate drain

10. Leak detection and vacuuming of system

11. Charging of Refrigerant 22

12. Testing