Procurement Summary
Country : Germany
Summary : Contract notice: Mass spectrometer
Deadline : 02 Nov 2018
Other Information
Notice Type : Tender
TOT Ref.No.: 26909556
Document Ref. No. : 407678-2018
Competition : ICB
Financier : Self Financed
Purchaser Ownership : -
Tender Value : Refer Document
Purchaser's Detail
Purchaser : LEIBNIZ-INSTITUT FÜR GEMÜSE-UND ZIERPFLANZENBAU GROßBEEREN/ERFURT E. V.
Office Name: Leibniz-Institut für Gemüse-und Zierpflanzenbau Großbeeren/Erfurt e. V.
Address: Theodor-Echtermeyer-Weg 1
Town: Großbeeren
Postal Code: 14979
Phone: +49 33701-78114
Fax: +49 33701-55391
Germany
Email :vw-ltg@igzev.de
URL :www.igzev.de
Tender Details
Object of the contract
Mass spectrometer
Description: Contract notice: Mass spectrometer
Authority Type: Other
Contact Nature: Supplies
Procedure: Open procedure
Document: Contract notice
Regulation: European Union
Award criteria: The most economic tender
CPV code: 38433100, 38433100
CPV Description: Mass spectrometer.
Mass spectrometer
Reference Number: 2018_LC-MS / MS System
LC-MS / MS System
Main Site: Leibniz Institute of Vegetable and Ornamental Plants Grossbeeren / Erfurt e. V. Theodor-Echtermeyer-Weg 1 14979 Grossbeeren
LC-MS / MS System
With the following requirements for the source
- API source with heating of the LC columns up to 400C and support of exchangeable ion sources: ESI, APCI, DART, Nanospray,
- ESI compatible with flow rates from 1 uL / min to 1 mL / min, without splitting,
- APCI compatible with flow rates from 50 uL / min to 2 mL / min, without splitting,
- Nanospray compatible with Flow rates from 1 nL / min to 50 μL / min,
- Dual CCD cameras (X, Y position) for fine positioning,
API source with automatic tuning program.
Mass analyzer
- Desktop,
- Dual quadrupole orbitrap-in series,
- mass range: m / z 50-6 000, with continuous ionic isolation with an ion window of 0.4 to 2 450 Da across the entire mass range,
- mass accuracy: 1 ppm RMS for internal and 3 for external calibration,
- Data acquisition modes: full scan, selected ion monitoring scan, product ion scan, parallel reaction monitoring, multiplex SIM and multiplex MS / MS modes with up to-10 Selected Vorlaeuferionen, data independent acquisition, neutral loss scans, retention time scheduled SIM and MS / MS scan,
- mass resolution: 140 000 at m / z 200 for all scan modes and both polarities,
- Linear dynamic range of 5 000: 1,
- polarity change: a spectrum in positive and negative mode in 1s with a resolution of 35 000,
- scan rate: full scan or SIM modewith up to 12 scans per second with a resolution of 17, 500 at m / z 200, MS / MS scan mode at up to 10 scans per second with a resolution of 17, 500 at m / z 200,
- Collision energy profiling for using different collision energies for HCD fragmentation,
- No external cooling, no gases other than nitrogen (nitrogen supply is guaranteed),
- Maximum dimensioning: 95 x 85 x 95 cm.
Nano-UHPLC
- Full compatibility with mass spectrometer,
- Works with nano, capillary and micro flow rates,
- Pressure resistance up to 1000 bar,
- 2-way / 6-port injection valve,
- Sample tempering from 4-45C (up to 22C below room temperature), - - Injection volume from 0-20 μl,
- Autosampler with up to 3 well plates (96 or 384, standard autosampler vials),
- Full and partial loopfeninjection and microliter pick-up,
starter kit, including C18 columns for peptide separation,
- Maximum dimension: 45 x 100 x 55 cm.
Control and evaluation software
- Complete control of the mass spectrometer and the nanoUHPLC under one software,
- Evaluation software supports various search algorithms (SEQUEST, Z-Core, Mascot) and combines the output of different algorithms-for cross-validation of results,
evaluation software supports various fragmentation techniques (CID, HCD, ETD),
absolute quantification by peptide labeling (TMT, iTRAQ), and relative quantification (label-free),
generation of a false discovery rate in protein identification,
- Support of data interpretation by automatic GO annotation, PTM site detection andDatabase Search, Delivery, Installation and Briefing
- No Charge for Delivery, Installation and Briefing
Training
- 2 Days Mass Spectrometer Training, On-Site,
- 2 Days Fluid Chromatography Training, On-Site,
- 1 Day Training for evaluation software, either on site or at the manufacturer,
maintenance
- maintenance contract for 24 months (start of contract after expiry of de12-month warranty, including warranty extension, annual maintenance and software updates),
- labor and travel time costs and spare parts included,
- service on site within 3 working days.
According to minimum requirements of the Brandenburg Procurement Law
Announcement ID: CXP9YRZD45Z
Internet address (URL): www.igzev.de
Documents
Tender Notice