HÔPITAL NEUCHÂTELOIS - DIRECTION LOGISTIQUE - SERVICE INGÉNIERIE BIOMÉDICALE ET ACHATS has floated a tender for 1 mri 3t for neuchatel hospital - la chaux-de-fonds website. The project location is Switzerland and the tender is closing on 31 Oct 2018. The tender notice number is 1037657, while the TOT Ref Number is 26956107. Bidders can have further information about the Tender and can request the complete Tender document by Registering on the site.

Expired Tender

Procurement Summary

Country : Switzerland

Summary : 1 mri 3t for neuchatel hospital - la chaux-de-fonds website

Deadline : 31 Oct 2018

Other Information

Notice Type : Tender

TOT Ref.No.: 26956107

Document Ref. No. : 1037657

Competition : ICB

Financier : Self Financed

Purchaser Ownership : -

Tender Value : Refer Document

Purchaser's Detail

Purchaser : HÔPITAL NEUCHÂTELOIS - DIRECTION LOGISTIQUE - SERVICE INGÉNIERIE BIOMÉDICALE ET ACHATS
Service demandeur/Entité adjudicatrice Hôpital neuchâtelois - Direction logistique Service organisateur/Entité organisatrice Hôpital neuchâtelois - Direction logistique - Service ingénierie biomédicale et achats, à l'attention de Farhat M'Madi, Rue de la Maladière 45,, 2000 Neuchâtel, Suisse, Téléphone +41 (0) 32 713 30 07,
Switzerland
Email :farhat.mmadi@h-ne.ch
URL :www.simap.ch

Tender Details

1 mri 3t for neuchatel hospital - la chaux-de-fonds website
this invitation to tender concerns the acquisition, installation, commissioning, user training, maintenance and scalability of a 3t mri with its faraday cage for the neuchatelois hospital. Site of la chaux-de-fonds.

2.7 place of supply



hospital neuchatelois -site la chaux-de-fonds

2.8 duration of the contract, framework agreement or system ofdynamic acquisition



18 months since the signing of the contract

this contract may be renewed: no



2.9 options



yes

description of options: obligatory options: - 1 “whole body“ antenna - 1 hand and wrist antenna options optional option 1 - 1 “medium“ surface antenna option 2 - 1 cardiac antenna option 3 - sequence for the limitatmetal artifact option 4 - sequence for acoustic noise limitation  measurable in db option 5 - sequence using simultaneous excitation of several sections to reduce the time required for neuroradiology, abdominal, ent and osteoarticular examinations. Option 6 - dynamic sequence for abdominal mri to visualize the arterial phasearrival of the contrast product which minimizes the risk of acquisition at the wrong time of arrival of the bolus option 7 - 3d sequence echo - with a good temporal resolution (acquisition of several time phases in a single apnee option 8 1 additional workstation option 9 - terminal replicating the acquisition console available near the magnett option 10 - a lighting fixture solution for the patient. Option 11 - an aid for programming patients with devices (cardiac implants for example) option 12 - a contrast agent injector option 13- a non-magnetic reanimation trolley option 14 a height-adjustable non-magnetic stretcher option 15 a non-magnetic wheelchair atwith removable armrests option 16 technology compresse sensing option 17 a non-magnetic perfusion for cardiac imaging option 18 2 very high resolution surface antennas (imaging of the temporomandibular joint atm

2.10 award criteria



in accordance with the criteria cited in the documents

2.11 are variants allowed



no



2.12 are partial offers accepted



no



2.13 delivery time



beginning 01.04.2019 and ending 30.05.2019



3.

Documents

 Tender Notice